eyes with large disc cupping and normal intraocular pressure: using optical coherence tomography to discriminate those with and without glaucoma

نویسندگان

tiago s. prata federal university of sã£o paulo, rua sena madureira, 1500 - vila mariana, sã£o paulo - sp, 04021-001, brazil glaucoma unit, hospital medicina dos olhos, rua salã©m bechara, 297 - centro, osasco - sp, 06018-180, brazil

syril dorairaj department of ophthalmology, mayo clinic, 4500 san pablo road, jacksonville, florida, 32224, usa

luisa trancoso glaucoma unit, hospital medicina dos olhos, rua salã©m bechara, 297 - centro, osasco - sp, 06018-180, brazil

fabio n. kanadani glaucoma unit, hospital medicina dos olhos, rua salã©m bechara, 297 - centro, osasco - sp, 06018-180, brazil

چکیده

we evaluated the ability of spectral-domain optic coherence tomography (sd-oct) to differentiate large physiological optic disc cupping (lpc) from glaucomatous cupping in eyes with intraocular pressure (iop) within the normal range.â  we prospectively enrolled patients with glaucoma or presumed lpc. participants â had optic discs with confirmed or suspected glaucomatous damage (defined as a vertical cup-to-disc ratio≥0.6), and all eyes had known untreated iop<21 mmhg. for glaucomatous eyes, a reproducible glaucomatous visual field (vf) defect was required. lpc eyes required normal vf and no evidence of progressive glaucomatous neuropathy (follow-up≥30 months). peripapillary retinal nerve fiber layer (prnfl) and macular ganglion cell complex (gcc) thicknesses were obtained using sd-oct. for all studied parameters of prnfl and gcc thicknesses, eyes with glaucoma (n=36) had significantly thinner values compared to eyes with lpc (n=71; p<0.05 for all comparisons). in addition, prnfl parameters had sensitivity of 66.7% and specificity of 83.1%, and gcc parameters had sensitivity of 61.2% and specificity of 81.7%. the combination of the two analyses increased the sensitivity to 80.6%. in conclusion, while evaluating patients with large optic disc cupping and iop in the statistically normal range, sd-oct had only limited diagnostic ability to differentiate those with and without glaucoma. although the diagnostic ability of the prnfl and the gcc scans were similar, these parameters yielded an increase in sensitivity when combined, suggesting that both parameters could be considered simultaneously in these cases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eyes with Large Disc Cupping and Normal Intraocular Pressure: Using Optical Coherence Tomography to Discriminate Those With and Without Glaucoma

We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertica...

متن کامل

Optic disc perfusion in eyes with primary open angle glaucoma and normal tension glaucoma using optical coherence tomography-based microangiography

Program Number: 2957 Poster Board Number: A0306 Presentation Time: 8:30 AM–10:15 AM Optic disc perfusion in eyes with primary open angle glaucoma and normal tension glaucoma using optical coherence tomography-based microangiography Karine D. Bojikian1, Chieh-Li Chen2, Joanne C. Wen1, Qinqin Zhang2, Chen Xin2, Divakar Gupta1, Raghu C. Mudumbai1, Murray A. Johnstone1, Ruikang K. Wang2, 1, Philip ...

متن کامل

Eyes with Suspicious Appearance of the Optic Disc and Normal Intraocular Pressure: Using Clinical and Epidemiological Characteristics to Differentiate Those with and without Glaucoma

Among all glaucoma suspects, eyes with optic nerve head features suspicious or suggestive of early glaucoma are probably those that offer the greatest challenge for clinicians. In contrast with the robust longitudinal data published on ocular hypertension, there is no specific management guideline for these patients. Therefore, evaluating eyes with suspicious optic disc appearance and normal in...

متن کامل

Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based Microangiography

PURPOSE To investigate optic disc perfusion differences in normal, primary open-angle glaucoma (POAG), and normal tension glaucoma (NTG) eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. DESIGN Cross-sectional, observational study. SUBJECTS Twenty-eight normal, 30 POAG, and 31 NTG subjects. METHODS One eye from each subject was scan...

متن کامل

Discriminating between Glaucoma and Normal Eyes Using Optical Coherence Tomography and the ‘Random Forests’ Classifier

PURPOSE To diagnose glaucoma based on spectral domain optical coherence tomography (SD-OCT) measurements using the 'Random Forests' method. METHODS SD-OCT was conducted in 126 eyes of 126 open angle glaucoma (OAG) patients and 84 eyes of 84 normal subjects. The Random Forests method was then applied to discriminate between glaucoma and normal eyes using 151 OCT parameters including thickness ...

متن کامل

Biomechanical Responses of Lamina Cribrosa to Intraocular Pressure Change Assessed by Optical Coherence Tomography in Glaucoma Eyes.

Purpose The purpose of this study was to measure change in anterior lamina cribrosa depth (ALD) globally and regionally in glaucoma eyes at different intraocular pressures (IOP). Methods Twenty-seven glaucoma patients were imaged before and after IOP-lowering procedures using optical coherence tomography. The anterior lamina was marked in approximately 25 locations in each of six radial scans...