in vitro comparison of conventional film and direct digital radiography in proximal caries detection

نویسندگان

seiedeh tahereh mohtavipour oro-maxillofacial developmental diseases research center, department of oral and maxillofacial radiology, guilan university of medical sciences, dental faculty, rasht, iran

fatemeh shahsavari department of oral & maxillofacial pathology, dental branch, islamic azad university, tehran, iran

alieh sadat javadzadeh haghighat oro-maxillofacial developmental diseases research center, department of oral and maxillofacial radiology, guilan university of medical sciences, dental faculty, rasht, iran

seiedeh saeideh mohtavipour department of pediatric dentistry, shahid beheshti university of medical sciences, dental faculty, tehran, iran

چکیده

introduction: various systems for intraoral digital radiography have been available as an alternative to film–based radiography. in consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im age quality and elimination of processing, it has been extensively used in different fields of denti stry in recent years. the purpose of this study was comparison of conventional film and digital radiography in the proximal caries diagnosis. materials and methods: in this in vitro study, 60 extracted premolar teeth were selected and mounted in acrylic blocks. the teeth were radio-graphed using f-speed film and a complementary metal oxide semiconductor digital sensor (cmos). two observers evaluated interproximal surfaces for detection of presence and extent of caries. true caries depth was determined by his tological examination. the diagnostic accuracy of each radiographic system were assessed by means of receiver operating characteristic curve (roc) analysis. results: there was no significant difference be-tween two imaging modalities. the az values in cases without caries and dentinal caries were greater than caries restricted to enamel and den tino enamel junction (dej). the differences among observers also were not statistically sig-nificant. conclusion: both imaging modalities were com-parable in the detection of proximal carious le-sions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

The Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries

Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a den...

متن کامل

In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries.

OBJECTIVES To compare the diagnostic accuracy of conventional film, unenhanced direct digital and inversion grayscale direct digital imaging in the detection of approximal caries. METHODS 150 approximal surfaces of extracted permanent molars and premolars were selected for the study on the basis of varying lesion depth. The teeth were radiographed using Ektaspeed Plus film; digital images wer...

متن کامل

Comparison of direct digital and conventional radiography for the detection of proximal surface caries in the mixed dentition.

PURPOSE The aim of this study was to compare the performance of direct digital radiography and traditional dental radiography for the detection of proximal surface dental caries in the mixed dentition. METHODS 15 quadrants of extracted teeth, arranged from the primary canine to permanent first molar, were imaged using direct digital (Schick Technologies, Long Island City, NY, USA) and convent...

متن کامل

Estimation of Remnant Dentin Thickness under Proximal Caries Using Digital Bitewing Radiography: An In-Vitro Study

Objectives: In restorative dentistry, it is essential to estimate the amount of remnant tooth structure after caries removal to make the best treatment plan. The present study was aimed to determine whether there is a correlation between the real thickness of remnant dentin under carious lesion and the radiographical measurement from photostimulable phosphor plates (PSPs). Methods: a whole numb...

متن کامل

diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries

objectives: this study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. materials and methods: fifty extracted human premolars and molars were mounted in a silicone block. charge-coupled device (ccd) and photostimulable phosphor plate (psp) receptors and intra-oral films were exposed with 60 and 70 kvp wit...