comparison of accuracy and observer agreement in the detection of simulated external root resorption using conventional digital radiography and digitally filtered radiography

نویسندگان

neda hajihassani department of endodontics, dental school, qazvin university of medical sciences, qazvin, iran

maryam tofangchiha department of oral and maxillofacial radiology, dental school, qazvin university of medical sciences, qazvin, iran

mojtaba hossein nahtaj private practice, qazvin, iran

چکیده

introduction: external root resorption is a clinical problem that often cannot be detected clinically. thus, radiography plays a crucial role in its diagnosis. however, optimal radiographic quality with minimal radiation exposure {2.1 [en] verify english word/phrase choice} is an important factor in selecting the appropriate radiographic technique. the aim of this study was the comparison of accuracy and observer agreement in the detection of simulated external root resorption using conventional digital radiography and digitally filtered radiography. materials and methods: the study was performed using 100 single rooted teeth in a dry mandibular jaw. the teeth were divided into 5 groups as follows: (1) without resorption, (2) resorption with 0.25 mm depth on buccal surface, (3) resorption with 0.5 mm depth on buccal surface, (4)resorption with 0.25 mm depth on proximal surfaces, and (5) resorption with 0.5 mm depth on proximal surfaces. digital radiographic images, both conventional and digitally filtered using 3 filters (diagonal, horizontal, and vertical), were obtained. the 2 groups of images were then evaluated by 4 observers in 2 stages, with an interval of 1 week. thereafter, sensitivity, accuracy, specificity, and kappa coefficients were calculated to assess observer agreement. results: for digitally filtered radiography with diagonal, horizontal, and vertical filters, the accuracy values were 86.5%, 87.2%, and 89.2% sensitivity values were 93.1%, 92.7%, and 94.3% and specificity values were 82.5%, 87.5%, and 93.7%, respectively. the accuracy, sensitivity, and specificity values for conventional digital radiography were 86.5%, 91.5%, and 82.5%, respectively. conclusion: manipulation of images in digital radiographic systems may not always facilitate diagnosis.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

INTRODUCTION External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled d...

متن کامل

accuracy of conventional and digital radiography in detecting external root resorption

introduction: external root resorption (err) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. the aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (cr) in comparison with digital radiographic techniques, i.e. charge-coupled ...

متن کامل

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Diagnosis of simulated external root resorption using conventional intraoral film radiography, CCD, PSP, and CBCT: a comparison study.

BACKGROUND Diagnosis of external root resorption (ERR) cavities may be challenging, especially when no clinical signs are seen. Therefore, the aim of this study was to compare the efficacy of conventional intraoral film radiography, charge-coupled device (CCD) detector, photostimulable phosphor plate (PSP) detector, and cone beam computed tomography (CBCT) for the detection of ERR. METHODS Th...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentomaxillofacil radiology, pathology and surgery

جلد ۳، شماره ۳، صفحات ۲۱-۲۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023