moderate patient-prosthesis mismatch has no negative effect on patients’ functional status after aortic valve replacement with carbomedics prosthesis
نویسندگان
چکیده
conclusions moderate ppm has no negative effect on echocardiographic trans-aortic pressure gradients or the patients’ nyha functional status after avr with a carbomedics prosthesis in the mid-term follow up. results of the 66 studied patients, 39 were male and 27 were female. the mean age of the patients was 43 ± 17 with a range of 6 - 76 years. implanted sizes of the carbomedics av prosthesis in 22 patients were 19 and 21 mm, and in 44 patients were 23 and 25 mm. eleven patients had moderate ppm (ieoa < 0.85 cm2/m2) and 55 of them did not have ppm (ieoa ≥ 0.85 cm2/m2). there were no statistically significant differences between the two groups in the echocardiographic trans-aortic pressure gradients (35.6 ± 19 vs. 23.2 ± 16 mmhg; p = 0.061) and the mean nyha functional classification (1.10 ± 0.3 vs. 1.01 ± 0.10; p = 0.074) after avr in the mid-term follow up. background patient-prosthesis mismatch (ppm) after aortic valve replacement (avr) is the subject of continuing debate in the cardiac surgery field. objectives the aim of this study was to evaluate the frequency and severity of patient-prosthesis mismatch (ppm) and the functional status of patients undergoing aortic valve replacement (avr) using a carbomedics prosthesis in the mid-term follow up. patients and methods we retrospectively studied 66 consecutive patients who were referred to avr with a carbomedics prosthesis at the rajaie cardiovascular medical and research center, a university referral hospital in tehran, iran. the severity of ppm as well as clinical and echocardiographic parameters and the patients’ new york heat association (nyha) functional classification status, operative data and postoperative complications, and mortality in a mid-term (4 - 5 months) follow up period was assessed. severe ppm was defined as the effective orifice area (eoa) indexed to the patient’s body surface area (bsa) < 0.65 cm2/m2 and moderate ppm was defined as the indexed effective orifice area (ieoa) between 0.65 and 0.85 cm2/m2.
منابع مشابه
Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients’ Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis
BACKGROUND Patient-prosthesis mismatch (PPM) after aortic valve replacement (AVR) is the subject of continuing debate in the cardiac surgery field. OBJECTIVES The aim of this study was to evaluate the frequency and severity of patient-prosthesis mismatch (PPM) and the functional status of patients undergoing aortic valve replacement (AVR) using a CarboMedics prosthesis in the mid-term follow ...
متن کامل[Moderate patient-prosthesis mismatch has no independent effect on 30-day mortality after isolated aortic valve replacement].
INTRODUCTION AND OBJECTIVES It is still not clear whether the presence of a moderate patient-prosthesis mismatch after isolated aortic valve replacement can increase 30-day mortality. The aim of this study was to determine whether a moderate mismatch is an independent predictor of early global or cardiac mortality after aortic valve replacement. METHODS The study involved 272 adult patients (...
متن کاملPatient-prosthesis mismatch in patients with aortic valve replacement
OBJECTIVE Patient-prosthesis mismatch (PPM) may affect clinical outcomes in patients with aortic valve replacement (AVR). We retrospectively examined the PPM in patients with isolated AVR in the Japan Adult Cardiovascular Surgery Database (JACVSD). METHODS We examined all patients with isolated AVR between January 1, 2008 and December 31, 2009. The JACVSD data collection form has a total of 2...
متن کاملProsthesis-patient mismatch after "high-risk" aortic valve replacement.
S ince the initial description of prosthesispatient mismatch (PPM) more than 3 decades ago (1), the clinical import of PPM after surgical aortic valve replacement (SAVR) has been debated in the surgical published data. The phenotypic manifestation of PPM is an elevated aortic valve gradient after valve implantation. Although a number of indices have been used to characterize the frequency of PP...
متن کاملProsthesis-patient mismatch affects survival after aortic valve replacement.
BACKGROUND Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "pros...
متن کاملProsthesis-patient mismatch in the transcatheter aortic valve replacement era.
In an insightful report in 1978, Rahimtoola (1) pointed to the fact that “mismatch can be considered to be present when the effective prosthetic valve area, after insertion into the patient, is less than that of a normal human valve.” He recognized that most patients have some residual aortic stenosis after aortic valve replacement and suggested that moderate or severe residual aortic stenosis ...
متن کاملمنابع من