Zero-Sequence Voltage Injection Method for DC Capacitor Voltage Balancing of Wye-Connected CHB Converter under Unbalanced Grid and Load Conditions
نویسندگان
چکیده
Leg capacitor energy balancing control is one of the crucial issues for stable operation a cascaded H-bridge (CHB) converter. Because this topology inherently consists numerous submodule cells with DC capacitors, cell voltages and leg instantaneously fluctuate depending on sequence CHB In general, wye-connected CHB-converter-based static synchronous compensator (STATCOM) utilizes zero-sequence voltage component balancing. paper, to improve dynamics control, feedforward calculation method injection proposed. The term can be calculated by using information from measured currents, ensures successful regulation balance even under unbalanced grid load conditions. Moreover, verification proposed supported mathematical vector theorems. A 50MVA full-scale CHB–STATCOM system simulation was performed verify considering as well
منابع مشابه
Voltage Equalization of DC Link capacitors in a CHB-Based PET under the Unbalance Voltage Conditions
The unbalance currents injection by power electronic transformers in order to improve the unbalance voltage conditions of the network causes an imbalanced voltage in the DC link capacitors and creates an active powers inequality in the different phases. In this paper, the proposed control structure independently controls the active power of each phase by modifying the power angle between the vo...
متن کاملZero Phase Sequence Voltage Injection for the Alternate Arm Converter
The Alternate Arm Converter (AAC) is a voltage source converter being developed as an alternative to the Modular Multilevel Converter (MMC) for HVDC power transmission and reactive power compensation. Each Arm of the converter contains high voltage series IGBT Director Switches and full-bridge cells, which enables the VSC to ride through AC and DC network faults. This paper describes how the AA...
متن کاملControl of Grid Integrated Voltage Source Converters under Unbalanced Conditions
............................................................................................................................................... I PREFACE................................................................................................................................................ III CONTENT ..........................................................................................
متن کاملSliding Mode Control of a Grid-Connected Distributed Generation Unit under Unbalanced Voltage Conditions
The increasing presence of inverter-based distributed generation (DG) units in distribution networks (DNs) requires control methods that achieve high performance not only during normal operating conditions, but also under unbalanced conditions. With a high probability, a type of voltage unbalance in DNs is unequal three-phase voltage magnitudes at the fundamental system frequency. This can occu...
متن کاملDC-DC Boost Converter with Constant Output Voltage for Grid Connected Photovoltaic Application System
The main purpose of this paper is to introduce an approach to design a DC-DC boost converter with constant output voltage for grid connected photovoltaic application system. The boost converter is designed to step up a fluctuating solar panel voltage to a higher constant DC voltage. It uses voltage feedback to keep the output voltage constant. To do so, a microcontroller is used as the heart of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2021
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en14041019