X‐ray scatter correction for multi‐source interior computed tomography
نویسندگان
چکیده
منابع مشابه
Demonstration of dose and scatter reductions for interior computed tomography.
With continuing developments in computed tomography (CT) technology and its increasing use of CT imaging, the ionizing radiation dose from CT is becoming a major public concern particularly for high-dose applications such as cardiac imaging. We recently proposed a novel interior tomography approach for x-ray dose reduction that is very different from all the previously proposed methods. Our met...
متن کاملA scheme for multisource interior tomography.
Currently, x-ray computed tomography (CT) requires source scanning so that projections can be collected from various orientations for image reconstruction. Limited by the scanning time, the temporal resolution of CT is often inadequate when rapid dynamics is involved in an object to be reconstructed. To meet this challenge, here the authors propose a scheme of multisource interior tomography fo...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملRobust moving-blocker scatter correction for cone-beam computed tomography using multiple-view information
Scatter contamination is one of the main sources of decreasing the image quality in cone-beam computed tomography (CBCT). The moving blocker method is economic and effective for scatter correction (SC), which can simultaneously estimate scatter and reconstruct the complete volume within the field of view (FOV) from a single CBCT scan. However, at the regions with large intensity transition in t...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...