XAFS at the new materials science beamline 10 at the DELTA storage ring
نویسندگان
چکیده
منابع مشابه
A New XAFS Beamline NW10A at the Photon Factory
A new XAFS beamline NW10A using bending magnet radiation from 6.5 GeV PF-AR has been constructed. NW10A consists of a Si(311) double crystal monochromator and a Pt-coated bent cylindrical focusing mirror and provides focused X-ray beam between 8 and 42 keV. The obtained flux through a 1mm square slit is 1×10 ph/s at 20 keV and 7×10 ph/s at 30keV, which are 20 and 200 times more intense than obt...
متن کاملThe Materials Science beamline upgrade at the Swiss Light Source
The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics ...
متن کاملHARWI-II, The New High-Energy Beamline for Materials Science at HASYLAB / DESY
Abstract. The GKSS Forschungszentrum Geesthacht, Germany, will setup a new high-energy beamline specialized for texture, strain and imaging measurements for materials science at the Hamburger Synchrotronstrahlungslabor HASYLAB of the Deutsches Elektronen-Synchrotron DESY. Four different experiments will be installed at the new wiggler HARWI-II. The high pressure cell will be run by the GFZ Pots...
متن کاملBiological XAFS at the BioCAT Undulator Beamline 18ID at the APS
The Biophysics Collaborative Access Team (BioCAT) undulator beam line at the Advanced Photon Source, Argonne, IL is a user facility devoted to the study of partially ordered and disordered biological materials by X-ray scattering, diffraction and absorption spectroscopy. Two sagital focussing, double-crystal (Si(111) and Si(400)) monochromators and a 1 mmirror provide monochromatic, horizontall...
متن کاملImprovement in XAFS beamline BL01B1 at SPring-8
Beamline BL01B1 was constructed for conventional XAFS measurements using a bending magnet light source at SPring-8 in 1997 [1]. BL01B1 covers a wide energy range from 3.8 to 113 keV using an adjustable inclined double-crystal monochromator and a double mirror system. Here, we describe a newly developed apparatus and the current status of the BL01B1. A time-efficient QEXAFS method was developed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2016
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/712/1/012026