X-ray spectral microanalysis of W-Ni-Fe pseudoalloy obtained from electroerosive powders
نویسندگان
چکیده
The results of X-ray spectral microanalysis W-Ni-Fe pseudo-alloy, obtained from electroerosive powders, are presented. Consolidation the powders was carried out by method spark plasma sintering using SPS 25-10 system. Using an EDAX energy-dispersive analyzer built into a Quanta 600 FEG scanning electron microscope, characteristic spectra were at various points on sample surface and along transverse section. As result study, it found that investigated sintered sample, tungsten, nickel iron contained as main elements, oxygen, copper chromium also present in small amounts.
منابع مشابه
X-ray diffraction peak profile analysis of maraged Fe-Ni-Mn steels
X-ray diffraction peak profile analysis was used to identify changes in the lattice distortions during isothermal aging of Fe-10Ni-7Mn (wt. %) maraging steel. Integral peak breadths were analyzed using classical Williamson-Hall equation taking the elastic anisotropy into account. It was found that substantial lattice distortions rise during precipitation hardening which depend strongly on the s...
متن کاملX-Ray microanalysis of stratified specimens
This paper presents a description of the state of the art methodology and software for the application of x-ray microanalysis to thin surface layers and more generally to the characterization of stratified specimens. The sensitivity of the technique to near-surface segregation is demonstrated. Some emphasis is given on the eS(pz) function (the distribution in depth of the primary generated x-ra...
متن کاملx-ray diffraction peak profile analysis of maraged fe-ni-mn steels
x-ray diffraction peak profile analysis was used to identify changes in the lattice distortions during isothermal aging of fe-10ni-7mn (wt. %) maraging steel. integral peak breadths were analyzed using classical williamson-hall equation taking the elastic anisotropy into account. it was found that substantial lattice distortions rise during precipitation hardening which depend strongly on the s...
متن کاملStrategies for Low Accelerating Voltage X-ray Microanalysis of Sub-Micrometer Features with the FE-EPMA
X-ray microanalyses of sub-micrometer features require that a lower accelerating voltage be used. This reduction in the accelerating voltage reduces the penetrating distance of the beam electrons and thereby reduces the analytical volume. Two general strategies have been proposed for achieving the smallest analytical volume. The first approach involves significantly reducing the accelerating vo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC web of conferences
سال: 2021
ISSN: ['2261-236X', '2274-7214']
DOI: https://doi.org/10.1051/matecconf/202134401001