X-ray phase-contrast imaging at 100 keV on a conventional source
X-ray grating interferometry is a promising imaging technique sensitive to attenuation, refraction and scattering of the radiation. Applications of this technique in the energy range between 80 and 150 keV pose severe technical challenges, and are still mostly unexplored. Phase-contrast X-ray imaging at such high energies is of relevant scientific and industrial interest, in particular for the ...
متن کاملX-ray phase contrast imaging: From synchrotrons to conventional sources
— Phase-based approaches can revolutionize X-ray imaging and remove its main limitation: poor image contrast arising from low attenuation differences. They exploit the unit decrement of the real part of the refractive index, typically 1000 times larger than the imaginary part driving attenuation. This increases the contrast of all details, and enables the detection of features classically consi...
متن کاملPhase contrast X - ray imaging
In the last decade X-ray imaging based on phase contrast greatly advanced thanks to the use of unmonochromatic synchrotron hard X-rays. The recent advances are going beyond microradiology and microtomography to reach nanometre scale. This paper reviews basic theory and selected applications to biomedical and materials sciences. The forthcoming improvements in phase contrast X-ray imaging will l...
متن کاملPhase-Contrast X-ray imaging
Virtually all X-rays imaging in a medical or biological context is performed by measuring differences in the attenuation of X-rays by the tissues. The material properties are inferred from the differences in the number of photons detected at the end of defined paths in the sample. Naturally then this form of X-ray imaging concentrates almost entirely on the particle side of X-ray behaviour. The...
متن کاملPropagation-based x-ray phase-contrast imaging with broad focus conventional x-ray sources
A propagation-based x-ray phase-contrast imaging (PBI) setup using a conventional x-ray source (LFF Cu target) is presented. A virtual x-ray source of 40 x 50 μm was created by using, horizontally, a 6 take-off angle (with the x-ray tube working in the line focus geometry) and, vertically, a 50 μm slit . The sample was set 12 m from the source. Propagation-based x-ray phase-contrast (PB) image ...