X-Ray Fluorescence Analysis with Si (Li) Semiconductor Detector
نویسندگان
چکیده
منابع مشابه
Characterising a Si(Li) detector element for the SIXA X-ray spectrometer
The detection efficiency and response function of a Si(Li) detector element for the SIXA spectrometer have been determined in the 500 eV to 5 keV energy range using synchrotron radiation emitted at a bending magnet of the electron storage ring BESSY, which is a primary radiation standard. The agreement between the measured spectrum and the model calculation is better than 2%. PACS: 95.55.Ka; 07...
متن کامل- iii - LBL - 647 TRACE ELEMENT ANALYSIS WITH SEMICONDUCTOR DETECTOR X - RAY SPECTROMETERS *
A method of obtaining high sensitivity and precision in x-ray fluorescence analysis using semiconductor detector spectrometers is discussed. Monoenergetic exciting radiation is employed to generate characteristic x-rays from trace elements in thin, uniform specimens. Corrections for absorption effects are determined; enhancement effects are omitted as they are negligible for many thin specimens...
متن کاملACCURACY, REPRODUCIBILITY AND SCOPE FOR X-RAY MICROANALYSIS WITH Si(Li) DETECTORS
The current state of the art for x-ray microanalysis is discussed with particular reference to accuracy and limits of detection, corrections for peak overlap and use of "windowless" detectors . It is now about ten years since reports appeared in the literature claiming that Si(Li) spectrometers (EDS) could be used for routine electron microprobe x-ray analysis giving results with accuracy compa...
متن کاملX-Ray Fluorescence Analysis of Gemstones
The energy dispersive X-ray fluorescence analysis (ED-XRFA) is a well-established tool for multielement composition analysis in different fields/1/. It works non-conducting and it is non-destructive. No particular sample preparation is necessary if the specimens have an almost planar and smooth surface. For the characterization of precious gemstone material it is also important that the deposit...
متن کاملSpatially resolved X-ray fluorescence analysis with a pyroelectric X-ray emitter.
A portable instrument for two-dimensional X-ray fluorescence imaging was assembled with an X-ray source using a pyroelectric crystal, which was driven by a 9-V dry battery, a Si-PIN detector, a slit, and pulse motors. Line scanning for a mug and a knife-edge-scan of an iron sheet were carried out using this spectrometer. The sensitivity of the spectrometer was sufficient for elemental analysis ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Tetsu-to-Hagane
سال: 1974
ISSN: 0021-1575,1883-2954
DOI: 10.2355/tetsutohagane1955.60.13_1910