X-ray Flat Panel Detector (FPD) for Medical application

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system

The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE;MS90Tj) system to an FPD (Shimadzu;SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examinat...

متن کامل

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging.

The continuing research and further development in flat panel detector technology have led to its integration into more and more medical x-ray systems for two-dimensional (2D) and three-dimensional (3D) imaging, such as fixed or mobile C arms. Besides the obvious advantages of flat panel detectors, like the slim design and the resulting optimum accessibility to the patient, their success is pri...

متن کامل

Direct-conversion flat-panel X-ray image detectors

Flat-panel X-ray image detectors have been shown to be suitable to replace the conventional X-ray filmjscreen cassettes for medical radiography (static or snapshot imaging). They are capable of capturing the X-ray image digitally immediately after the X-ray exposure which permits a convenient clinical transition to digital radiography. There are two general approaches to the flat-panel X-ray de...

متن کامل

Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal sys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Visualization Society of Japan

سال: 2000

ISSN: 1884-037X,0916-4731

DOI: 10.3154/jvs.20.1supplement_357