X-ray computed tomography imaging of polymer gel dosimeters
نویسندگان
چکیده
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملAn experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography.
Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comono...
متن کاملX-ray Computed Tomography for Medical Imaging
Themathematical principles of computed tomography (CT) were first investigated by J. Radon [28] as early as 1917 and were later extended to complex fields by Kirillov [22]. The first application of tomography was, surprisingly, in radio astronomy [2], and today, it finds usage in diverse fields such as medical imaging, seismology, and underwater acoustic imaging. In medical imaging, CT has had ...
متن کاملAccuracy and reproducibility in x-ray computed tomography polymer gel dosimetry
This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...
متن کاملPolymer gel dosimetry using x-ray computed tomography: a feasibility study.
A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N(CT)-dose response) and the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2006
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/56/1/009