X-ray beam deflection control with a flexible capillary

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-flux hard X-ray microbeam using a single-bounce capillary with doubly focused undulator beam

A pre-focused X-ray beam at 12 keV and 9 keV has been used to illuminate a single-bounce capillary in order to generate a high-flux X-ray microbeam. The BioCAT undulator X-ray beamline 18ID at the Advanced Photon Source was used to generate the pre-focused beam containing 1.2 x 10(13) photons s(-1) using a sagittal-focusing double-crystal monochromator and a bimorph mirror. The capillary entran...

متن کامل

Controlling X-ray beam trajectory with a flexible hollow glass fibre

A metre-length flexible hollow glass fibre with 20 µm-bore and 1.5 mm-cladding diameters for transporting a synchrotron X-ray beam and controlling the trajectory has been examined. The large cladding diameter maintains a moderate curvature to satisfy the shallow glancing angle of total reflection. The observed transmission efficiency was more than 20% at 12.4 keV. As a demonstration, a wide-are...

متن کامل

Convergent-beam diffraction of ultra-short hard X-ray pulses focused by a capillary lens

We report the generation of diffraction patterns using X-ray pulses from a fs-laser plasma focused by an X-ray capillary lens to a spot size smaller than 100 μm. A thin moving iron tape is irradiated at 10 Hz with 200 mJ/130 fs titanium–sapphire laser pulses. Fe Kα (λ= 0.194 nm) radiation emitted from the rear side of the tape is focused to a spot by the capillary lens resulting in an intensity...

متن کامل

X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.

PURPOSE The feasibility of medical imaging using a medical linear accelerator to generate acoustic waves is investigated. This modality, x-ray acoustic computed tomography (XACT), has the potential to enable deeper tissue penetration in tissue than photoacoustic tomography via laser excitation. METHODS Short pulsed (μs-range) 10 MV x-ray beams with dose-rate of approximately 30 Gy∕min were ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2013

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/425/5/052017