X-Parameter Measurement of Pulse-Compression Nonlinear Transmission Lines

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmission of Solitary Pulse in Dissipative Nonlinear Transmission Lines

A class of dissipative complex Ginzburg–Landau (DCGL) equations that govern the wave propagation in dissipative nonlinear transmission lines is solved exactly by means of the Hirota bilinear method. Two-soliton solutions of the DCGL equations, from which the one-soliton solutions are deduced, are obtained in analytical form. The modified Hirota method imposes some restrictions on the coefficien...

متن کامل

Nonlinear Magnetoinductive Transmission Lines

Power transmission in one-dimensional nonlinear magnetic metamaterials driven at one end is investigated numerically and analytically in a wide frequency range. The nonlinear magnetic metamaterials are composed of varactor-loaded split-ring resonators which are coupled magnetically through their mutual inductances, forming thus a magnetoiductive transmisison line. In the linear limit, significa...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

X-ray pulse compression using strained crystals

The use of strained crystals to time-compress chirped x-ray FEL pulses is proposed. The chirped beam diffracts from a crystal in which the strain varies with depth. Low-Z crystals are favored to reduce absorption over the required path lengths and small Bragg angles are favored to increase the diffraction efficiency of the strained crystal. The best compression ratios found for a 230 fs, 0.5% c...

متن کامل

On the Transmission Line Pulse Measurement Technique

Transmission Line Pulse is a short pulse (25ns to 150ns) measurement of the current-voltage (I/V) characteristics of the ESD protection built into an integrated circuit. The short TLP pulses are used to simulate the short ESD pulse threats and integrated circuit must tolerate without being damaged. In this work the fundamental principles of how the TLP pulse is generated and used to create I-V ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Electrical and Computer Engineering

سال: 2010

ISSN: 2090-0147,2090-0155

DOI: 10.1155/2010/415315