Working length changes in curved canals after coronal flaring by using rotary files and hand file: An in vitro study
نویسندگان
چکیده
منابع مشابه
Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملeffectiveness of hedstroum files and rotary k3 instruments in removal of obturation materials during retreatment in curved canals
چکیده ندارد.
15 صفحه اولComparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...
متن کاملcomparison of working length determination using apex locator and conventional radiography in curved canals-an in vitro study
introduction: the exact measurement of the root canal length is of great importance in root canal therapy. although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. the purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملمقایسه تأثیر سیستمهای چرخشی Profile و Race بر آناتومی اولیه کانالهای مشابهسازی شده دارای انحنای شدید
Background and Aim: Recent advances in technology have permitted manufacturers to produce endodontic files from NiTi alloy and rotary systems. According to manufacturers, these files maintain original canal shape better than hand files and reduce treatment time. The aim of this study was to compare a new rotary system (Race) with an older one (Profile) in maintaining the original shape of curve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Conservative Dentistry
سال: 2013
ISSN: 0972-0707
DOI: 10.4103/0972-0707.117489