Wireless Ion-Selective Electrode Autonomous Sensing System
نویسندگان
چکیده
منابع مشابه
Lanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملChromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملComputer-controlled ion-selective electrode switch
The construction of a microcomputer-controlled electrode switch for use in potentiometric determinations is described. This can be coupled to most of the analytical equipment usually found in laboratories, to enable a setting up of automatic systems capable of performing sequential determinations with several ion-selective electrodes. The assessment of its analytical usage and behaviour are dis...
متن کاملMeasurements with fluoride ion selective electrode
Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Sensors Journal
سال: 2011
ISSN: 1530-437X,1558-1748
DOI: 10.1109/jsen.2011.2122331