Winding Method of Transformer for Zero-Sequence and Negative-Sequence Harmonic Elimination
نویسندگان
چکیده
منابع مشابه
New Methods for Harmonic Reduction in T. C. R. by Sequence Control of Transformer Taps
Thyristor controlled static compensators consist of two basic schemes, TCR and TSC. Owing to the discontinuous current in TCR, current harmonics are generated in the supply system. This paper introduces two methods for the reduction of these harmonics. On the basis of the coordination or uncoordination of turn ratios with harmonic reduction levels, each method is described in two alternative sc...
متن کاملSensitivity and Specificity of Nucleic Acid Sequence-Based Amplification Method for Diagnosis of Cutaneous Leishmaniasis
Abstract Background and Objective: Culture, microscopic method is a gold standard method for identification of Lishmania parasite. The use of Molecular methods such as RT- PCR compared to microscopic methods has a higher sensitivity and specificity however, it is not widely used due to its expensive equipment and the time requested. The use of nucleic acid sequence based amplification (NASBA) ...
متن کاملOne Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage
This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...
متن کاملThree-Winding Autotransformer Fault Study and Impact on Protection Application
Autotransformers (ATs) have been widely used for many years. For large size ATs, a tertiary winding is usually included. Sometimes the tertiary winding is loaded for station service, local loads, VAR compensation, etc. Other times, the tertiary winding is buried and acts as stabilizing winding which provides a path for zero-sequence current and 3rd harmonic current. Three-winding ATs present so...
متن کاملA harmonic elimination and suppression scheme for an open-end winding induction motor drive
In this paper, a harmonic elimination and suppression scheme for a dual-inverter-fed open-end winding induction motor drive is presented. Two isolated dc-link sources with voltage ratio of approximately 1 : 0.366 are required for the present drive. These two isolated dc links feeding two inverters to drive the openend winding induction motor eliminate the triplen harmonic currents from the moto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Transactions of The Korean Institute of Electrical Engineers
سال: 2014
ISSN: 1975-8359
DOI: 10.5370/kiee.2014.63.7.896