Wind tunnel test on H-section cross arm of transmission tower

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical simulation of water entry of tunnel cross section with different deadrise angles and tunnel radiuses

This study deals with the numerical modeling of symmetrical water entry of tunneled sections. In this study, firstly, the water entry problem of a wedge section without tunnel in four different deadrise angles was numerically modeled. The obtained results related to the pressure distribution on these sections and the maximum pressure have been compared with the experiment results. In the next s...

متن کامل

Wall Interference and Boundary Simulation in a Transonic Wind Tunnel With a Discretely Slotted Test Section

A computational simulation of a transonic wind tunnel test section with longitudinally slotted walls is developed and described herein. The nonlinear slot model includes dynamic pressure e ects and a plenum pressure constraint, and each slot is treated individually. The solution is performed using a nite-di erence method that solves an extended transonic small disturbance equation. The walls se...

متن کامل

Cross Section Effects on Convergence-Confinement Method in Multi Stage Tunnel Excavation

Dimensionless coefficient () in convergence confinement method shows the relaxation of stress in the wall of the tunnel at different excavation movements. This factor is considered a constant number in previous studies and tunnel geometric characteristics (such as depth, cross-section shape, radius, soil material, etc.) are not included in its determination; however, ignoring these effects can...

متن کامل

Wind Turbine Tower Resonance

Wind turbine towers are large structures designed to withstand the unique loading conditions imposed on them by the turbine’s nacelle and dynamic forces from the rotating blades. Observations and noise measurements of a particular wind turbine showed high noise levels at approximately 48 Hz, which could not be explained from the usual known potential noise sources. Correlated far field noise me...

متن کامل

Effects of Additional Diaphragms on the Wind-Resistant Performance of Power Transmission Tower

By field investigation, it is found that the lower section of transmission tower body is the critical position for insuring tower’s integral stability under strong wind. For improving tower’s wind-resistant performance, the scheme of adding diaphragms at mid-height of diagonal members in lower tower body was proposed and its static effectiveness was researched by static loading tests. Taking th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Wind Engineers, JAWE

سال: 1998

ISSN: 1883-8413,0912-1935

DOI: 10.5359/jawe.1998.77_15