Wind Effects in Tall Buildings for Vertical Irregularity

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Learning Design Rules for Wind Bracings in Tall Buildings

This paper describes a methodology for applying machine learning to problems of conceptual design, and presents a case study of learning design rules for wind bracings in tall buildings. Design rules are generated by induction from examples of minimum weight designs. This study investigates the applicability of machine learning methods which are capable of constructive induction, that is of aut...

متن کامل

Interference effects of wind loads on a row of tall buildings

ABSTRACT: We apply CFD to visualize wind flow around a row of three square-plan tall buildings closely arranged in a row. Increase in wind load on the upwind building is observed when wind blows to the row at 30. CFD results show that the interference mechanism is mainly due by strong channeling of wind flow through the building gaps. This leads to highly negative pressures on building walls fa...

متن کامل

Wind Effects on Lowrise Buildings

In the opening decades of wind engineering research and application the typical focus was on the glamorous, highrise structure. These expensive projects could typically afford the high cost of a wind-tunnel study. As the relative cost of these studies has decreased over the last forty years, more conventional architecture has found its way into the wind tunnel. However, it is still quite rare f...

متن کامل

Hybrid Analysis of Meso-meteorological Model and Les for Strong Wind in Dense Tall Buildings

This paper provides an appropriate method for predicting strong winds acting on tall buildings erected in close proximity to one another at the center of a city. We first check the accuracy of strong winds estimated using the meso-meteorological model (MM5) without an urban-canopy model above and inside an urban canopy, in comparison with the observational data taken at the rooftop of a high-ri...

متن کامل

Effects of Column Shortening in Tall R.c. Buildings

In tall and very tall reinforced concrete buildings, long term column shortening due to creep and shrinkage affects the service life behavior of structural elements. Creep-induced column shortening depends on the axial stress level in the column cross sections and on its evolution in time. For this reason, the construction method and phases must be taken into account as a key factor in defining...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology

سال: 2020

ISSN: 2321-9653

DOI: 10.22214/ijraset.2020.6701