Wideband Active Load–Pull by Device Output Match Compensation Using a Vector Network Analyzer
نویسندگان
چکیده
This work investigates wideband active load-pull (WALP) on microwave electron devices with a standard vector network analyzer (VNA), solely using calibrated frequency-domain relative measurements. Differently from the methods requiring full time-domain waveform acquisition capabilities, this approach removes any instantaneous bandwidth (BW) requirement, allowing to target modulated signals arbitrarily large BWs. A VNA-based measurement setup is presented, and novel mathematical framework developed in order enable synthesis of an arbitrary load profile suitable numerical algorithms. linear precompensation LS output match device, here implemented by different methods, shown significantly improve speed stability basic secants' iterative method used reach target. Performance results, investigating convergence properties effects dynamic range, are reported for gallium nitride (GaN) high-electron-mobility transistor (HEMT) up 120-MHz BW sub-6-GHz range.
منابع مشابه
Vector-Network-Analyzer Calibrations
We develop an uncertainty analysis that captures the dominant sources of measurement error in state-of-the-art WM-380 (WR 1.5) rectangular-waveguide vector-network-analyzer measurements over the frequency range 500–750 GHz. We use the analysis to assess thru-reflect-line, thru-short-match, and thru-short-radiating-open calibrations. The comparison shows that thru-short-match and thru-short-radi...
متن کاملLow-cost Vector Network Analyzer for Biomedical Applications
A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...
متن کاملElectronic Vector - Network - Analyzer Verification ■
118 October 2009 Digital Object Identifier 10.1109/MMM.2009.933595 The National Institute of Standards and Technology (NIST) recently introduced a new electronic approach for verifying microwave vectornetwork-analyzer (VNA) calibrations with a single computer-controlled electronic verifi cation artifact. The verifi cation results are captured in easy-tounderstand performance metrics that, unlik...
متن کاملWideband optical vector network analyzer based on optical single-sideband modulation and optical frequency comb.
A novel approach to increase the measurement range of the optical vector network analyzer (OVNA) based on optical single-sideband (OSSB) modulation is proposed and experimentally demonstrated. In the proposed system, each comb line in an optical frequency comb (OFC) is selected by an optical filter and used as the optical carrier for the OSSB-based OVNA. The frequency responses of an optical de...
متن کاملDetermination of Permeability from Impedance Measurement Using Vector Network Analyzer
This study treats the optimised one-port (reflection coefficient) and two-port (shunt-through/series-through) measurement methods for complex permeability determination of solid soft magnetic materials using a vector network analyzer (VNA) at frequencies from 9 kHz to 6.5 GHz. The principle of measurement methods, the relationships of measured phasor voltage ratio (Sparameter) to complex impeda...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Microwave Theory and Techniques
سال: 2021
ISSN: ['1557-9670', '0018-9480']
DOI: https://doi.org/10.1109/tmtt.2020.3034713