Which orthodontic archwire sequence? A randomized clinical trial

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Which orthodontic archwire sequence? A randomized clinical trial.

The aim of this study was to compare three orthodontic archwire sequences. One hundred and fifty-four 10- to 17-year-old patients were treated in three centres and randomly allocated to one of three groups: A = 0.016-inch nickel titanium (NiTi), 0.018 x 0.025-inch NiTi, and 0.019 x 0.025-inch stainless steel (SS); B = 0.016-inch NiTi, 0.016-inch SS, 0.020-inch SS, and 0.019 x 0.025-inch SS; and...

متن کامل

Pain reduction after initial archwire placement in orthodontic patients: a randomized clinical trial.

INTRODUCTION The aim of this study was to compare the efficacy of ibuprofen, viscoelastic bite wafers, and chewing gum in reducing orthodontic pain. METHODS This randomized clinical trial included 50 girls between the ages of 13 and 18 years classified into 5 groups of 10 each: placebo, ibuprofen (400 mg), chewing gum, soft viscoelastic wafer, and hard viscoelastic wafer. The patients in each...

متن کامل

Acupuncture for chronic nonpulsatile tinnitus: A randomized clinical trial

Background: There is challenge to find an effective treatment for tinnitus. Few studies were done on the effects of acupuncture on tinnitus. This study evaluated the effect of acupuncture on chronic non-pulsatile tinnitus. Methods: This randomized double-blind clinical trial was conducted from December 2014 to September 2015. Patients suffering from chronic non-pulsatile tinnitus were randomly...

متن کامل

Simulation and Analysis of Orthodontic Archwire Bending Robot

A 3D mathematical model of orthodontic archwire with rectangular curve is established. Simplified 3D solid model of orthodontic archwire bending robot, which is consistent of bending die, support structure and archwire are established by Creo software, then the simplified model of bending die is put into ANSYS Workbench. Material parameters the contact condition and boundary conditions are set ...

متن کامل

Clinical Outcomes of Intramedullary and Extramedullary Fixation in Unstable Intertrochanteric Fractures: A Randomized Clinical Trial

Background: The best method for repairing intertrochanteric fractures is still controversial. The fixation methods includeextramedullary (EM) and intramedullary (IM). Studies that compare IM and EM fixations for unstable hip fractures arerare. In this study, our goal was to compare the efficacy of EM and IM fixation in treatment of unstable intertrochantericfractures.Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The European Journal of Orthodontics

سال: 2006

ISSN: 0141-5387,1460-2210

DOI: 10.1093/ejo/cjl030