Which intraperitoneal insufflation pressure should be used for less postoperative pain in transperitoneal laparoscopic urologic surgeries?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Which intraperitoneal insufflation pressure should be used for less postoperative pain in transperitoneal laparoscopic urologic surgeries?

PURPOSE To determine whether using different intraperitoneal insufflation pressures for transperitoneal laparoscopic urologic surgeries decreases postoperative pain. MATERIALS AND METHODS 76 patients who underwent transperitoneal laparoscopic upper urinary tract surgery at different insufflation pressures were allocated into the following groups: 10mmHg (group I, n=24), 12mmHg (group II, n=25...

متن کامل

Intraperitoneal Ropivacaine Instillation for Postoperative Pain Relief after Laparoscopic Cholecystectomy

130 Correspondence to: Hyun Kang, Department of Anesthesiology and Pain Medicine, College of Medicine, Chung-Ang University, 224-1, Heukseok-dong, Dongjak-gu, Seoul 156-755, Korea. Tel: 02-62992571, Fax: 02-6299-2585, E-mail: [email protected] Received February 22, 2010, Accepted May 4, 2010 Intraperitoneal Ropivacaine Instillation for Postoperative Pain Relief after Laparoscopic Cholecystectomy

متن کامل

Urologic Laparoscopic Surgeries in Elderly: Analysis of Pre-Operative Risk Factors and Postoperative Complications

Purpose: The aging of the population leads to increases in the prevalence of symptomatic urologic diseases. The aim of this study is the analysis of pre-operative risk factors and postoperative complications in patients over the age of 60 years undergoing elective laparoscopic urologic surgery. Patients and Methods: A retrospective study was conducted of 113 patients 60 years of age or older wh...

متن کامل

MRS Shimming: An Important Point Which Should not be Ignored

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International braz j urol

سال: 2017

ISSN: 1677-5538

DOI: 10.1590/s1677-5538.ibju.2016.0366