Weibull approximation of LiDAR waveforms for estimating the beam attenuation coefficient

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Energy Dependence of the Photoelectric Attenuation Coefficient of Substances

Introduction: The photoelectric attenuation coefficient of substances is known to depend upon the energy E of the photon and the effective atomic number of substances (Zeff) as (Zeffx/Ey).  No definitive values about these indices x, y are given in the literature. The index x is said to lie between, 3.0 and 4.0, while for ‘y’ different values have been assigned, between 3.0 and 4.0. Method...

متن کامل

A model for estimating ultrasound attenuation along the propagation path to the fetus from backscattered waveforms.

Accurate estimates of the ultrasound pressure and/or intensity incident on the developing fetus on a patient-specific basis could improve the diagnostic potential of medical ultrasound by allowing the clinician to increase the transmit power while still avoiding the potential for harmful bioeffects. Neglecting nonlinear effects, the pressure/intensity can be estimated if an accurate estimate of...

متن کامل

Least – Squares Method For Estimating Diffusion Coefficient

 Abstract: Determination of the diffusion coefficient on the base of solution of a linear inverse problem of the parameter estimation using the Least-square method is presented in this research. For this propose a set of temperature measurements at a single sensor location inside the heat conducting body was considered. The corresponding direct problem was then solved by the application of the ...

متن کامل

LEAST – SQUARES METHOD FOR ESTIMATING DIFFUSION COEFFICIENT

Determining the diffusion coefficient based on the solution of the linear inverse problem of the parameter estimation by using the Least-square method is presented. A set of temperature measurements at a single sensor location inside the heat conducting body is required. The corresponding direct problem will be solved by an application of the heat fundamental solution.

متن کامل

Analysis of the Attenuation Coefficient of Composite Silicone Rubber and Gliceryn for Soft Tissue Phantom Applications

Introduction: Phantom is an object that can be used to investigate the accuracy of radiation dose delivered to patients. Phantom is usually produced from the combination of the silicone rubber as a matrix and glycerin as a filler to form a composite for the replacement of the human soft tissue. The composite is imaged using computed tomography (CT) simulator for the de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2016

ISSN: 1094-4087

DOI: 10.1364/oe.24.022670