Wearable speckle plethysmography (SPG) for characterizing microvascular flow and resistance
نویسندگان
چکیده
منابع مشابه
Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow.
BACKGROUND/AIMS Microvascular blood flow is essential for healing and predicts surgical outcome. The aim of the current study was to investigate the relation between fluxes measured with the laser speckle contrast imaging (LSCI) technique and changes in absolute blood flow. In addition, we studied the reproducibility of the LSCI technique when assessing the intra-abdominal microcirculation of t...
متن کاملMicrovascular pressure, flow, and resistance in spontaneously hypertensive rats.
Microvascular resistance (MVR), determined as the ratio of the second-order arteriolar blood pressure (servo-null method) to blood flow (dual-slit), was assessed in the cremaster muscle preparation of 7- to 8-week-old normotensive Wistar-Kyoto (WKY) rats and spontaneously hypertensive rats (SHR). The MVR was used as an index of resistance during 1) control conditions; 2) superfusion of graded c...
متن کاملMicrovascular blood flow resistance: role of endothelial surface layer.
Observations of blood flow in microvascular networks have shown that the resistance to blood flow is about twice that expected from studies using narrow glass tubes. The goal of the present study was to test the hypothesis that a macromolecular layer (glycocalyx) lining the endothelial surface contributes to blood flow resistance. Changes in flow resistance in microvascular networks of the rat ...
متن کاملOpen-flow plethysmography with pressure-decay compensation.
Whole-body plethysmography is widely used to measure ventilation in awake, unrestrained animals. However, the explicit solution for volumetric analysis of the plethysmograph signal depends upon a closed system, which limits experimental design. Although often used, open-flow plethysmography is complicated by the time-decay of pressure signals generated in the open chamber (e.g. equivalent volum...
متن کاملDevelopment of a Respiratory Inductive Plethysmography Module Supporting Multiple Sensors for Wearable Systems
In this paper, we present an RIP module with the features of supporting multiple inductive sensors, no variable frequency LC oscillator, low power consumption, and automatic gain adjustment for each channel. Based on the method of inductance measurement without using a variable frequency LC oscillator, we further integrate pulse amplitude modulation and time division multiplexing scheme into a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biomedical Optics Express
سال: 2018
ISSN: 2156-7085,2156-7085
DOI: 10.1364/boe.9.003937