Wear mechanism and debris analysis of PEEK as an alternative to CoCrMo in the femoral component of total knee replacement

نویسندگان

چکیده

Abstract The polyetheretherketone (PEEK)-highly cross-linked polyethylene (XLPE), all-polymer knee prosthesis has excellent prospects for replacing the traditional metal/ceramic-polyethylene joint prosthesis, improving service life of and quality patients’ life. long-term wear mechanism PEEK-XLPE is comprehensively evaluated from amount, morphology, debris compared to that CoCrMo-XLPE prosthesis. After 5 million cycles in vitro wear, loss XLPE (30.9±3.2 mg) lower than (32.1±3.1 mg). Compared CoCrMo-XLPE, plastic deformation more severe early stage, adhesive peeling adhesion are lighter later stage. size distribution relatively dispersed, which concentrated. Wear mainly flake block debris, was abrasive wear. volume per unit area PEEK femoral condyle (10.45×10 µm 3 /mm 2 ) higher CoCrMo (8.32×10 ). surface furrows adhesions, while corrosion spots. flakes blocks, shape rods blocks. adhesion, corrosion.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performanc...

متن کامل

the analysis of the role of the speech acts theory in translating and dubbing hollywood films

از محوری ترین اثراتی که یک فیلم سینمایی ایجاد می کند دیالوگ هایی است که هنرپیش گان فیلم میگویند. به زعم یک فیلم ساز, یک شیوه متأثر نمودن مخاطب از اثر منظوره نیروی گفتارهای گوینده, مثل نیروی عاطفی, ترس آور, غم انگیز, هیجان انگیز و غیره, است. این مطالعه به بررسی این مسأله مبادرت کرده است که آیا نیروی فراگفتاری هنرپیش گان به مثابه ی اعمال گفتاری در پنج فیلم هالیوودی در نسخه های دوبله شده باز تولید...

15 صفحه اول

Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation

The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR  is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study

New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Friction

سال: 2023

ISSN: ['2223-7690', '2223-7704']

DOI: https://doi.org/10.1007/s40544-022-0700-z