Weak interaction searches with cryogenic detectors
نویسندگان
چکیده
منابع مشابه
Dark matter detection with cryogenic detectors
Direct detection of dark matter in the form of Weakly-Interacting Massive Particles (WIMPS) is an active field of research. Cryogenic detectors have been in the forefront of the field, due to their exquisite ability to reject backgrounds from interactions of normal matter. In this paper, I describe the current status and future prospects for such experiments. 1. The landscape of dark matter dir...
متن کاملCryogenic X-ray detectors for synchrotron science.
Cryogenic detectors operated at temperatures below 1 K offer an order of magnitude higher energy resolution than conventional semiconductor-based energy-dispersive detectors, and orders of magnitude higher efficiency that grating spectrometers. Initially developed for astrophysics applications, these detectors are increasingly used in synchrotron-based research, both for detector characterizati...
متن کاملCryogenic Single Chip Electron Spin Resonance Detectors
Methods based on the electron spin resonance (ESR) phenomenon are used to study paramagnetic systems at temperatures that ranges from 1000 to below 1 K. Commercially available spectrometers achieve spin sensitivities in the order of 1010 spins/ p Hz at room temperature on sample with volumes in the order of few μl. This results can be improved by cooling the system at cryogenic temperatures, wh...
متن کاملIndium joints for cryogenic gravitational wave detectors
A viable technique for the preparation of highly thermal conductive joints between sapphire components in gravitational wave detectors is presented. The mechanical loss of such a joint was determined to be as low as 2×10 at 20 K and 2×10 at 300 K. The thermal noise performance of a typical joint is compared to the requirements of the Japanese gravitational wave detector, KAGRA. It is shown ...
متن کاملCryogenic ASICs in GaAs for Applications with Particle Detectors
We present two cryogenic Application Specific Integrated circuits (ASIC's) realized with a GaAs MESFET process. A single-channel differential or double-channel singleended voltage sensitive preamplifier for 4.2 K operation, to be used with bolometric detectors, was realized and tested. A very simple structure working as a unity gain buffer or as a transconductance amplifier, or even as a shapin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2000
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(99)01330-3