Wavelength Calibration Correction Technique for Improved Emissivity Retrieval
نویسندگان
چکیده
منابع مشابه
The millimeter wavelength emissivity in IC 5146
We have observed a core in the northern streamer of the IC5146 cloud using the MPIfR 19-channel Bolometer system on the IRAM 30m telescope at a wavelength of 1.2 mm. We smoothed our observations to the same angular resolution (30) as a new map of the NIR extinction of this cloud (Lada, Alves, and Lada 1998) and in this way obtained direct measurements of the ratio of millimeter emissivity to du...
متن کاملSTIS Calibration Enhancement: Wavelength Calibration and CTI
The Instrument Physical Modeling Group in the Space Telescope European Co-ordinating Facility has undertaken to examine aspects of STIS calibration and develop physical model based solutions where appropriate. Here we discuss two such aspects and the status of the model based solutions. The first concerns the derivation of dispersion solutions for the echelle spectroscopy modes. The second corr...
متن کاملProcedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers
This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it is necessary to acquire many partial spectra, each at a different angular position of the grating...
متن کاملRadiometric Method for Emissivity Retrieval in High Reflective Materials
High reflective materials in the microwave region play a very important role in the realization of antenna reflectors for a broad range of applications, including radiometry. These reflectors have a characteristic emissivity which needs to be characterized accurately in order to perform a correct radiometric calibration of the instrument. Such a characterization can be performed by using open r...
متن کاملInternal to external wavelength calibration
The spectra of Hen 1357 (the Stingray nebula) were used to check the internal to external wavelength calibration of the STIS first order CCD modes. The radial velocity of the Stingray nebula is known to high accuracy (< 1 km/sec) and the line with of the nebular line is very narrow (< 8 km/sec for the integrated nebula). Thus the observations of the Stingray nebula are ideal to check the intern...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
سال: 2020
ISSN: 1939-1404,2151-1535
DOI: 10.1109/jstars.2020.2968044