Wavefront aberration and contrast sensitivity after implantation of foldable and rigid iris claw phakic intraocular lenses: Artiflex versus artisan
نویسندگان
چکیده
منابع مشابه
Iris-claw (Artisan®/Artiflex®) phakic intraocular lenses for high myopia and high hyperopia
Ophthalmology Department, Hospital de Clínicas de Porto Alegre and OftalmoCentro, Porto Alegre, RS, Brazil Av. Nilo Peçanha, 724/401, Porto Alegre, RS, CEP 90.470-000, Brazil Author for correspondence: Tel.: +55 513 330 7733 Fax: +55 513 330 7733 [email protected] Artisan/Artiflex phakic intraocular lenses (pIOLs) demonstrate reversibility, high optical quality with better best specta...
متن کاملHigher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses.
PURPOSE To evaluate higher-order aberrations (HOAs) after implantation of Artiflex phakic intraocular lenses (pIOLs). SETTING Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands. METHODS This retrospective comparative case series comprised 27 eyes (14 patients) that had Artiflex pIOL implantation and 22 eyes (13 patients) that had Artisan pIOL implantation...
متن کاملChronic subclinical inflammation after phakic intraocular lenses implantation: Comparison between Artisan and Artiflex models
Purpose To compare chronic subclinical inflammation induced after implantation of Artisan vs. Artiflex phakic intraocular lenses (pIOLs). Methods This prospective, comparative, non-randomized study included consecutive patients with moderate to high myopia who underwent Artisan or Artiflex pIOL implantation with standard surgery and postoperative care. Anterior chamber flare was assessed quan...
متن کاملToxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation
Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterili...
متن کاملPosition of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography.
PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Op...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2016
ISSN: 0301-4738
DOI: 10.4103/0301-4738.185611