Waterhammer Caused by Valve Stroking in the Pipe Line with Two Valves
نویسندگان
چکیده
منابع مشابه
Waterhammer Caused by Intermittent Pump Failure in Pipe Systems Including Parallel Pump Groups
The use of pumps linked in parallel or series in large scale pipe systems is usually inevitable, to meet the required head and discharge. Transient flow occurs following a pump failure in a pump group as a result of variations in the flow rate. This research is an investigation about waterhammer caused by one or more pump-switch off in a pump group when they are connected in parallel. The opera...
متن کاملWaterhammer tests in a long PVC pipeline with short steel end sections
An experiment featuring waterhammer in viscoelastic pipes is presented in which the effects of pipe-wall viscoelasticity on waterhammer pressures are investigated. A large-scale pipeline apparatus made of polyvinyl chloride (PVC) at Deltares, Delft, The Netherlands, has been used to carry out waterhammer experiments. Tests have been conducted in a reservoir-pipeline-valve system consisting of a...
متن کاملTranscatheter valve-in-valve implantation for failed bioprosthetic heart valves.
BACKGROUND The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. ...
متن کاملTranscatheter valve-in-valve implantation for failed surgical bioprosthetic valves.
When bioprosthetic cardiac valves fail, reoperative valve replacement carries a higher risk of morbidity and mortality compared with initial valve replacement. Transcatheter heart valve implantation may be a viable alternative to surgical aortic valve replacement for high-risk patients with native aortic stenosis, and valve-in-valve (V-in-V) implantation has been successfully performed for fail...
متن کاملSubclinical Valve Thrombosis in Sutureless Bioprosthetic Valves
I n the current issue of JAHA, Dal en et al 1 report the results of a single-center prospective observational study of 47 patients with implantation of the Perceval sutureless bioprosthesis (LivaNova, Milan, Italy). Cardiac computed tomography (CT) performed at a median of 491 days (range 36– 1247 days) found hypo-attenuated leaflet thickening (HALT) in 18 (38%) and reduced leaflet motion (RLM)...