The purpose of our research is to validate an experimental method developed by Johnson and Cowen (2016) aimed at measuring volumetric discharge in open channel using Surface particle image velocimetry (SPIV) combined with turbulent boundary layer analysis infer the bathymetry calculate flow rate, ultimately extending this work natural systems (Hendrickson, 2020).
منابع مشابه
3D surface-imaging for volumetric measurement in people with obesity.
BACKGROUND Current methods for tracking the progress of people with obesity towards a weight loss goal appear simple and potentially misleading. A technique to quantify change in body shape whilst visualising areas of the body where weight loss occurs would be advantageous, and has the potential to be used as a motivational tool. Three-dimensional (3D) surface-imaging would serve as a good basi...
متن کاملStudy of Volumetric Flow Rate of a Micropump Using a Non-classical Elasticity Theory
The purpose of this research is to study the mechanical behavior of a micropump with clamped circular diaphragm which is the main component of drug delivery systems. In this paper, the non-linear governing equations of the circular microplate using Kirchhoff thin plate theory was been extracted based on the modified couple stress (MCST) and classical (CT) theories. Then, the non-linear equation...
متن کاملA Methodological Evaluation of Volumetric Measurement Techniques including Three-Dimensional Imaging in Breast Surgery
Breast surgery currently remains very subjective and each intervention depends on the ability and experience of the operator. To date, no objective measurement of this anatomical region can codify surgery. In this light, we wanted to compare and validate a new technique for 3D scanning (LifeViz 3D) and its clinical application. We tested the use of the 3D LifeViz system (Quantificare) to perfor...
متن کاملParticles Mass Flow Rate and Concentration Measurement Using Electrostatic Sensor
In many industries where flow parameters measurement is essential to control manufacturing process, the use of a reliable, cost effective and high accuracy instrument is an important issue. Appropriate measurement method and design leads to improvement of pneumatic conveyors operation and process efficiency. This paper present an instrumentation design based on passive charge detection using a ...