Volumetric absorptive microsampling as alternative sampling technique for renal function assessment in the paediatric population using iohexol

نویسندگان

چکیده

The glomerular filtration rate (GFR) is considered the best overall index for renal function. Currently, one of most promising exogenous markers GFR assessment iohexol. In this study, suitability volumetric absorptive microsampling (VAMS) as alternative conventional blood sampling and quantification iohexol in paediatric plasma was assessed. Therefore, a new, fully validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method developed. Subsequently, clinical evaluated 20 patients by comparing concentrations associated values obtained VAMS with those plasma. developed, simple cost-effective LC-MS/MS-method fulfilled all pre-set validation acceptance criteria. Iohexol could be accurately quantified within haematocrit range 20–60% long-term stability demonstrated up to 245 days under different storage temperatures. Both (r = 0.98, mean bias: −4.20%) derived 0.99; 1.31%), method, good correlation acceptable bias. agreement between two methods especially higher than 60 mL/min/1.73 m2. Nevertheless, <60 m2 accuracy compared lower. However, small adjustments protocol probably solve problem.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the individual renal function in chronic unilateral renal obstruction using functional CT as compared to 99mTc-DTPA renal scan

Introduction: The selection of   optimal treatment of obstructive nephrouropathy requires information about the functional status of each kidney. Nuclear renal scanning objectively measure differential renal function, multiple studies have demonstrated the role of assessment of renal perfusion and GFR with triphasic CT. The aim of this study is to assess the role of CT based on renal parenchyma...

متن کامل

assessment of the efficiency of s.p.g.c refineries using network dea

data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...

Renal Biopsy in Paediatric Population

OBJECTIVE: To find out the pattern of glomerulopathies in paediatric population, undergoing renal biopsy at Khyber Teaching Hospital, Peshawar. METHODS: This was a prospective study carried out at the department of Nephrology at Khyber Teaching Hospital, Peshawar from June 2010 till June 2012. Ultrasound guided percutaneous renal biopsies were carried out in patients with the finding of; 1) Nep...

متن کامل

Modified Sampling Strategies Using Correlation Coefficient for Estimating Population Mean

This paper proposes two sampling strategies based on the modified ratio estimator using the population mean of auxiliary variable and population correlation coefficient between the study variable and the auxiliary variable by Singh and Tailor (2003) for estimating the population mean (total) of the study variable in a finite population. A comparative study is made with usual sampling strategies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Chromatography B

سال: 2021

ISSN: ['1570-0232', '1873-376X']

DOI: https://doi.org/10.1016/j.jchromb.2021.122623