Right ventricular volume measurement by conductance catheter.
Continuous ventricular volume measurement by the conductance method assumes a homogeneous electrical field dispersed throughout and contained within the ventricle. Because of dense trabeculation and complex geometry, right ventricular (RV) volume description by this method may be seriously compromised. This study sought to determine the accuracy and limitations of RV volume measurement by condu...
متن کاملCalibrating volume measurements made using the dual-field conductance catheter
The conductance catheter technique allows realtime measurements of ventricular volume based on changes in the electrical conductance of blood within the ventricular cavity. Conductance volume measurements are corrected with a calibration coefficient, α, in order to improve accuracy. However, conductance volume measurements are also affected by parallel conductance, which may confound calibratio...
متن کاملLeft ventricular volume measurement by conductance catheter in intact dogs. Parallel conductance volume depends on left ventricular size.
The conductance catheter is a promising new instrument for continuously measuring left ventricular (LV) volume. Absolute LV volume (V[t]) is related to uncorrected conductance volume, B(t), according to the equation: V(t) = (1/alpha)(B(t) - alpha Vc). The alpha Vc factor represents parallel-conductance volume due to conducting material outside the LV blood pool, and may be estimated by transien...
متن کاملDetermination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique.
Using a multielectrode conductance catheter to estimate continuous left ventricular volume we determined the end-systolic pressure-volume relationship (ESPVR) in situ in open-chest anesthetized dogs. Dogs (n = 8) were studied in the control state and after pharmacologic sympathectomy (hexamethonium) and surgical vagotomy both before and after the administration of dobutamine. ESPVR was measured...
متن کاملAccuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts.
We evaluated the accuracy of the recently reported technique of estimating intraventricular volume by measurement of intracavitary electrical conductance in six isolated, ejecting, canine left ventricles. Left ventricular volumes were measured directly by a previously validated servosystem that employed an electroconductive balloon placed in the left ventricular cavity. The volume measured cont...