Voltammetric behaviour of biological macromolecules at arrays of aqueous|organogel micro-interfaces
نویسندگان
چکیده
منابع مشابه
Electrochemical behaviour and voltammetric sensitivity at arrays of nanoscale interfaces between immiscible liquids.
Arrays of nanoscale interfaces between immiscible electrolyte solutions were formed using silicon nitride nanopore array membranes. Nanopores in the range from 75 nm radius down to 17 nm radius were used to form the nano-interfaces. It was found that the liquid organic phase electrolyte solution filled the pores so that inlaid nano-interfaces were formed with the aqueous phase. Cyclic voltammet...
متن کاملVoltammetric Behaviour of Metronidazole at Mercury Electrodes
Metronidazol é o fármaco mais importante do grupo de 5-nitroimidazoles, possuindo toxicidade contra microrganismos anaeróbicos, sendo a molécula de DNA o principal alvo de sua ação biológica. O mecanismo de ação do metronidazol depende do processo de redução do grupo nitro e, em meio ácido, a redução é pH-dependente envolvendo quatro elétrons na completa redução ao derivado hidroxilamínico. Em ...
متن کاملBehaviour of proteins at interfaces.
The adsorption and conformational changes of three plasma proteins, (bovine) serum albumin, .y-globulin and fibrinogen, on several (bio)polymer surfaces are reported. A theory is developed which invokes reversible adsorption of the proteins in the initial stages and a time dependent conformational change of adsorbed protein leading to essentially irreversible long-term adsorption. In each case ...
متن کاملVoltammetric behaviour of brodimoprim at mercury and its determination in biological fluids using differential-pulse polarography
A differential-pulse polarographic (DPP) method was developed for the determination of brodimoprim (BDP) in Michaelis (MCL) buffer. The peak potential (Ep) occurs at 21.33 V (versus SCE) when the pH of the system is 4.0. The voltammetric behaviour in MCL buffer and the mechanisms of the electrode reaction were studied by, e.g., linear sweep voltammetry, cyclic voltammetry and normal-pulse polar...
متن کاملOptimisation of the conditions for stripping voltammetric analysis at liquid-liquid interfaces supported at micropore arrays: a computational simulation.
Micropore membranes have been used to form arrays of microinterfaces between immiscible electrolyte solutions (µITIES) as a basis for the sensing of non-redox-active ions. Implementation of stripping voltammetry as a sensing method at these arrays of µITIES was applied recently to detect drugs and biomolecules at low concentrations. The present study uses computational simulation to investigate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Chemistry Chemical Physics
سال: 2010
ISSN: 1463-9076,1463-9084
DOI: 10.1039/c003323e