Voltammetric Acetylcholine Sensor using Mercaptohydroquinone Monolayer-Attached Gold Electrode as the Base Transducer
نویسندگان
چکیده
منابع مشابه
Voltammetric response of phenylboronic acid monolayer-modified gold electrode to sugars.
The surface of a gold (Au) disk electrode was modified with a self-assembled monolayer consisting of phenylboronic acid moiety to fabricate a voltammetric sensor sensitive to sugars. The modified Au electrode exhibited a voltammetric response to sugars in the presence of Fe(CN)6(3-) ion in the sample solution at neutral pH. The peak current of the cyclic voltammograms decreased depending on the...
متن کاملAlumina nanoparticles modified carbon paste electrode as a new voltammetric sensor for determination of dopamine
The present study examines a new dopamine sensor based on Alumina nanoparticles modified carbon paste electrode (Al2O3NPsCPE). Moreover, the present study focuses on the electrochemical act of the Al2O3NPsCPE for the detection of dopamine by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). There is also a focus on the specification of the prepared modified electrode by electroc...
متن کاملSilica Nanoparticles Modified Carbon Paste Electrode as a Voltammetric Sensor for Determination of Diclofenac
The present study describes the use of a new carbon paste electrode modified by means of Silica nanoparticles prepared by a simple and rapid procedure for the determination of sodium diclofenac (DCF). Moreover, the present study focuses on the characterization of electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) of the prepared Silica NPs-CPE. In this work, The...
متن کاملVoltammetric microsensor using PEDOT-modified gold electrode for the simultaneous assay of ascorbic and uric acids
A voltammetric microsensor has been developed for the simultaneous assay of ascorbic (AA) and uric (UA) acids in aqueous solution. Theelectrode surface hasbeenmodifiedbymeansof electropolymerized conductive poly(3,4-ethylenedioxythiophene) PEDOT organic films. The electrocatalytic activity of the interface was dependent on the electropolymerization parameters inducing change in the structure an...
متن کاملElectrochemical sensor for immunoassay of carcinoembryonic antigen based on thionine monolayer modified gold electrode.
A sensor based on thionine monolayer modified gold electrode for determination of carcinoembryonic antigen (CEA) in human serum is proposed. The sensor is prepared by covalently binding thionine to a cysteamine self-assembled monolayer with p-phthaloyl chloride as a linkage, which gives a surface coverage of 8.97+/-3.28 x 10(-12)mol/cm(2) for thionine. The electrochemistry of the immobilized th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Denki Kagaku oyobi Kogyo Butsuri Kagaku
سال: 1997
ISSN: 0366-9297,2434-2556
DOI: 10.5796/kogyobutsurikagaku.65.487