Voltage instability identification with modified L-index using synchrophasor data
نویسندگان
چکیده
<p>In the prevailing open-access environment, one of limitations for power exchanges has been voltage stability. The study stability necessitates a complete network representation. In this paper, advantage dynamic behavior generators is considered by incorporating models generators. It shown resulted in more accurate results compared to conventional PV buses or ideal source that are used most studies. Moreover, traditional L-index augmented real-time and synchronized phasor data collected from optimally located measurement units (PMU) wide-area system (WAMS) estimate margins. Simulation studies carried out on IEEE 9-bus 14-bus systems under various conditions. demonstrated inclusion synchrophasor WAMS significantly improves precision with which analysis obtained.</p>
منابع مشابه
Model Validation Using Synchrophasor Data - - A Synchrophasor Success Story
Mathematical models – from models of individual transmission elements and power plant components to production cost models and system models -are used for every aspect of power system planning and operations. When a generator or system does not act in the way that its models predict, the mismatch between reality and the model-based expectations can lead to severe disturbances and costly equipme...
متن کاملOn-line Assessment of Voltage Stability using Synchrophasor Technology
Series of blackouts encountered in recent years in power system have been occurred because either of voltage or angle instability or both together was not detected within time and progressive voltage or angle instability further degraded the system condition, because of increase in loading. This paper presents the real-time assessment methodology of voltage stability using Phasor Measurement Un...
متن کاملData Identification using L-CBF
counting bloom filters (CBFs) are used to improve upon the energy, delay, and complexity of various processor structures. CBFs improve the energy and speed of membership tests by maintaining an imprecise and compact representation of a large set to be searched. This studies the energy, delay, and area characteristics of two implementations for CBFs using full custom layouts in a commercial 0.13...
متن کاملA Synchrophasor Based Optimal Voltage Control Scheme with Successive Voltage Stability Margin Improvement
1 Department of Electrical Engineering, Feng Chia University (FCU), No.100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan 2 Department of Information Engineering and Computer Science, Feng Chia University (FCU), No.100, Wenhwa Road, Seatwen, Taichung 40724, Taiwan; [email protected] 3 Department of Automatic Control Engineering, Feng Chia University (FCU), No.100, Wenhwa Road, Seatwen, Taichung...
متن کاملExtracting Steady State Components from Synchrophasor Data Using Kalman Filters
Abstract: Data from phasor measurement units (PMUs) may be exploited to provide steady state information to the applications which require it. As PMU measurements may contain errors and missing data, the paper presents the application of a Kalman Filter technique for real-time data processing. PMU data captures the power system’s response at different time-scales, which are generated by differe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indonesian Journal of Electrical Engineering and Computer Science
سال: 2021
ISSN: ['2502-4752', '2502-4760']