Voltage Control Performance of AWS Connected for Grid Operation
نویسندگان
چکیده
منابع مشابه
Model Predictive Control of Distributed Energy Resources with Predictive Set-Points for Grid-Connected Operation
This paper proposes an MPC - based (model predictive control) scheme to control active and reactive powers of DERs (distributed energy resources) in a grid - connected mode (either through a bus with its associated loads as a PCC (point of common coupling) or an MG (micro - grid)). DER may be a DG (distributed generation) or an ESS (energy storage system). In the proposed scheme, the set - poin...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملControl System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System
In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting of permanent magnet synchronous generator (PMSG) ...
متن کاملPerformance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT
The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Lo...
متن کاملOptimal Operation of Doubly-fed Induction Generator used in a Grid-Connected Wind Power System
In this paper, a wind power system based on a doubly-fed induction generator (DFIG) is modeled and simulated. To guarantee high-performance control of the powers injected into the grid by the wind turbine, five intelligent super-twisting sliding mode controllers (STSMC) are used to eliminate the active power and current ripples of the DFIG. The STSMC controller is a high-order sliding mode cont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Energy Conversion
سال: 2006
ISSN: 0885-8969
DOI: 10.1109/tec.2006.874220