Volar, Splitting, and Collapsed Type of Die‐Punch Fracture Treated by Volar Locking Plate ( VLP ): A Retrospective Study
نویسندگان
چکیده
منابع مشابه
Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation.
The current study investigated the incidence of complications after surgery for distal radial fractures. This multicenter retrospective study was conducted at 11 institutions. A total of 824 patients who had distal radius fractures that were treated surgically between January 2010 and August 2012 were identified. The study patients were older than 18 years and were observed for at least 12 week...
متن کاملBreakage of a volar locking plate after delayed union of a distal radius fracture.
This is a case report of a 58-year-old obese, diabetic female who sustained a dorsally angulated distal radius fracture, treated with a volar locking plate. Union was delayed and the plate broke. The fracture healed after repeated surgery involving replacement of the plate and grafting with demineralised bone matrix. Delayed unions of distal radius fractures are rare. This case shows that fract...
متن کاملFailure of volar locking plate fixation of an extraarticular distal radius fracture: A case report
BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plat...
متن کاملDistal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...
متن کاملMechanical failure of the distal radius volar locking plate.
PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopaedic Surgery
سال: 2020
ISSN: 1757-7853,1757-7861
DOI: 10.1111/os.12695