Vocal‐Tract Cross‐Sectional‐Area Measurements with the Impedance Tube
نویسندگان
چکیده
منابع مشابه
Impedance Measurements in the Kekb
In the KEKB storage rings, we have measured the current dependence of the betatron tunes and the damping rate to evaluate the broad-band transverse impedance. The measured impedances were cross-checked and exceeded the design value by a factor of more than five. The tranverse mode-coupling instability was observed in LER when chromaticity was reduced. We found that the main impedance source for...
متن کاملProjective Electrical Impedance Reconstruction with Two Measurements
This paper presents a projective reconstruction method of electrical impedance distribution using two boundary measurements of current-voltage data. The proposed method has a major advantage over existing electrical impedance tomography systems: relatively high resolution impedance image in a near-surface region underneath the voltage-sensing probe that is placed on a skin surface. We attach tw...
متن کاملAcoustic characterisation of liquid foams with an impedance tube.
Acoustic measurements provide convenient non-invasive means for the characterisation of materials. We show here for the first time how a commercial impedance tube can be used to provide accurate measurements of the velocity and attenuation of acoustic waves in liquid foams, as well as their effective "acoustic" density, over the 0.5-6kHz frequency range. We demonstrate this using two types of l...
متن کاملImpedance of a Beam Tube with Small Corrugations
In accelerators with very short bunches, such as is envisioned in the undulator region of the Linac Coherent Light Source (LCLS)[1], the wakefield due to the roughness of the beam-tube walls can have important implications on the required smoothness and minimum radius allowed for the beam tube. Of two theories of roughness impedance, one yields an almost purely inductive impedance[2], the other...
متن کاملImpedance measurements: some recent developments.
(1) With a modern impedance bridge and X-Y recorder, it is possible to obtain a great deal of information, not only on the nature of conductive lesions, but also on the site of sensorineural lesions. It is even possible now, using a white noise stimulus, to obtain an estimate of the pure tone hearing threshold, and since this is not only an objective test, but also a very simple one, it is pote...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Acoustical Society of America
سال: 1967
ISSN: 0001-4966
DOI: 10.1121/1.2144162