Visualization of Vaper Bubble on Subcooled Pool Boiling Heat Transfe from a Horizontal Cylinder
نویسندگان
چکیده
منابع مشابه
Highly subcooled pool boiling heat transfer at various gravity levels
A microscale heater array 2:7 mm 2:7 mm in size along with a video camera was used to provide subcooled pool boiling heat transfer measurements at gravity levels ranging from 1.8g to 10 g. The fluid was FC-72 at 1 atm and subcooled by nominally 36 C for all cases. A Terrier–Orion sounding rocket and the KC-135 aircraft were used to provide the microgravity and low-g environments, respectively. ...
متن کاملNumerical Simulations of the Dynamics and Heat Transfer Associated With a Single Bubble in Subcooled Pool Boiling
In this study, numerical simulations of a vapor bubble in subcooled pool boiling have been performed. The applied numerical procedure coupling level-set function with moving mesh method has been validated by comparing the results of bubble-growth history including bubble departure diameter with data from experiments. The predictions of bubble dynamics and heat transfer for various subcoolings a...
متن کاملSubcooled Pool Boiling Experiments on Horizontal Heaters Coated With Carbon Nanotubes
Pool boiling experiments were conducted with three horizontal, flat, silicon surfaces, two of which were coated with vertically aligned multiwalled carbon nanotubes (MWCNTs). The two wafers were coated with MWCNT of two different thicknesses: 9 m (Type-A) and 25 m (Type-B). Experiments were conducted for the nucleate boiling and film boiling regimes for saturated and subcooled conditions with l...
متن کاملHeater size and heater aspect ratio effects on subcooled pool boiling heat transfer in low - g
Pool boiling heat transfer measurements using heaters of varying aspect ratio were obtained in low-g (0.01 g ± 0.025 g) aboard the KC-135 aircraft. The heater aspect ratio was varied by selectively powering 2 · 2, 2 · 4, 2 · 6, 2 · 8, and 2 · 10 arrays of heaters in a 10 · 10 heater array containing individual heaters 0.7 · 0.7 mm in size. Electronic control circuitry was used to maintain an is...
متن کاملDirect Numerical Simulation of Subcooled Nucleate Pool Boiling
With the long-term objective of Critical Heat Flux (CHF) prediction, a Direct Numerical Simulation (DNS) framework for simulation of subcooled and saturated nucleate pool boiling is developed. One case of saturated, and three cases of subcooled boiling at different subcooling levels are simulated. Grid refinement study is also reported. Both boiling and condensation phenomena can be computed si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Visualization Society of Japan
سال: 1996
ISSN: 1884-037X,0916-4731
DOI: 10.3154/jvs.16.1supplement_183