VISUALIZATION OF FILLING DEFECTS IN A LIVER PHANTOM CONTAINING Tc99m, Hg197, I131 OR Au198 USING A RECTILINEAR SCANNER OR SCINTILLATION CAMERA
نویسندگان
چکیده
منابع مشابه
the effectiveness of strategy-based instruction in teaching english as a second or foreign language: a meta-analysis of experimental studies
a large number of single research studies on the effects of strategy-based instruction (sbi) in teaching english as a foreign or second language has been conducted so far. however, the lack of a comprehensive meta-analysis targeting the effectiveness of english language sbi is observed. moreover, the findings of experimental studies regarding the context of the english language, proficiency lev...
f/sla from learner perspectives: a social activity or a cognitive process
in the past couple of decades sociocultural theory of sla and its implications in efl contexts have attracted attentions of research circles worldwide and aroused some controversies. firth and wagner (1997) have questioned the principles of the cognitive view which gives importance to mental constructs in favor of sociocultural view which highlights social and contextual constructs. but if soci...
15 صفحه اولNeuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.
UNLABELLED High-dose administration of 131I-metaiodobenzylguanidine (131I-MIBG) continues to be a promising treatment for neuroblastoma. However, currently used methods of estimating 131I-MIBG uptake in vivo may be too inaccurate to properly monitor patient radiation exposure doses. To improve localization and uptake measurements over currently practiced techniques, we evaluated different metho...
متن کاملCamera Scans – Using a Digital Camera as a Film Scanner
Individual photographers and institutions are struggling with large film archives that require digitizing. Digital cameras can fill an important gap in the scanning environment, enabling large collections to be scanned on-site with low-cost equipment and easily-trained operators. Digital camera scans can now produce very high-quality images, suitable for nearly any kind of reproduction. This pa...
متن کاملRapid evaluation of weekly scintillation camera resolution and linearity using the orthogonal tri-hole phantom.
OBJECTIVE Both state and federal regulations require weekly monitoring of the resolution and linearity of the scintillation camera. Several phantoms are available to perform this quality control function. These include the quadrant bar. Bureau of Radiological Health (BRH), and orthogonal-hole (OH) phantoms. Each of these phantoms has either functional or temporal limitations on its use. The ort...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Roentgenology
سال: 1967
ISSN: 0361-803X,1546-3141
DOI: 10.2214/ajr.101.3.551