Vibration velocity control standard of buried pipeline under blast loading of adjacent tunnel

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soil-Structure Interaction of Buried Pipes Under Cyclic Loading Conditions

The safety of lifelines, as the most important urban facilities, under different conditions highly depends on the safe design and performance of these buried structures. This cannot be achieved unless their actual behaviors are well understood and considered at the designing stage. A new physical model was developed in Amirkabir University of Technology to study the behavior of buried pipes und...

متن کامل

Blast Mitigation Analysis of Semi-Buried Structure

Semi-buried structures are most commonly used at first line of defense along the border between two countries. This demands investigation of their dynamic behaviour under blast loading. Herein, a semi-buried structure with foam sandwiched walls and buttresses to reduce the effect of blast is analysed. The effect of provision of different configurations of buttresses and foam core between two la...

متن کامل

An Electrochemical Measurement for Evaluating the Cathodic Disbondment of Buried Pipeline Coatings under Cathodic Protection

Steel pipelines are susceptible to corrosion by the action of corrosive substance in the environment and one of the most common failure modes in buried pipeline coatingis cathodic disbondment. Consequently, Electrochemical Impedance Spectroscopy (EIS) was used to assess the effect of three important parameters, the thickness of coating, the artificial defect ...

متن کامل

Prognostics implementation of electronics under vibration loading

In this paper, a methodology is developed for monitoring, recording, and analyzing the life-cycle vibration loads for remaining-life prognostics of electronics. The responses of printed circuit boards to vibration loading in terms of bending curvature are monitored using strain gauges. An analytical model calibrated by finite element analysis is developed to calculate the strain at interconnect...

متن کامل

Finite Element Analysis for CFST Columns under Blast Loading

The columns of frame structures are the key load-bearing components and the exterior columns are susceptible to attack in terrorist blasts. When subjected to blast loads, the columns would suffer a loss of bearing capacity to a certain extent due to the damage imparted which may lead to their collapse and even cause the progressive collapse of the whole structure . The concrete-filled steel col...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Soils and Foundations

سال: 2019

ISSN: 0038-0806

DOI: 10.1016/j.sandf.2019.12.003