Vibration Suppression of Wind/Traffic/Bridge Coupled System Using Multiple Pounding Tuned Mass Dampers (MPTMD)

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibration suppression of cables using tuned inerter dampers

This paper considers the use of a tuned inerter damper (TID) system for suppressing unwanted cable vibrations. The TID consists of an inerter, a device that exerts a force proportional to relative acceleration, coupled with a parallel spring and damper. It may be thought of as similar to a tuned-mass-damper, but requiring two terminals. As a two terminal device, the performance of the TID is co...

متن کامل

Semiactive Tuned Mass Dampers

Studies have already demonstrated the successful use of linear semiactive damping devices, such as variable orifice (VO) dampers, for semiactive TMD systems. More recently, nonlinear semiactive damping devices, such as magnetorheological (MR) dampers, have also been shown to be effective for semiactive control of TMDs. Though semiactive dampers differ widely, with responses ranging from linear ...

متن کامل

THE CAPABILITY OF OPTIMAL SINGLE AND MULTIPLE TUNED MASS DAMPERS UNDER MULTIPLE EARTHQUAKES

The main focus of this research has been to investigate the effectiveness of optimal single and multiple Tuned Mass Dampers (TMDs) under different ground motions as well as to develop a procedure for designing TMD and MTMDs to be effective under multiple records. To determine the parameters of TMD and MTMDs under multiple records various scenarios have been suggested and their efficiency has be...

متن کامل

dual-layer multiple tuned mass dampers for vibration control of structures

the performance of dual-layer multiple tuned mass dampers (dl-mtmd) with uniformly distributed natural frequencies is investigated. the dl-mtmd consists of one large tuned mass damper (l-tmd) and an arbitrary number of small tuned mass dampers (s-tmd). the primary structure is represented as a single degree-of-freedom system which corresponds to a specific vibration mode to be controlled in a r...

متن کامل

MINIMIZING HANKEL’S NORM AS DESIGN CRITERION OF MULTIPLE TUNED MASS DAMPERS

Tuned mass damper (TMD) have been studied and installed in structures extensively to protect the structures against lateral loads. Multiple tuned mass dampers (MTMDs) which include a number of TMDs with different parameters have been proposed for improving the performance of single TMDs. When the structural system is considered as multiple degrees of freedom (MDOF) and implemented with MTMDs, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2019

ISSN: 1424-8220

DOI: 10.3390/s19051133