Vibration Feature Analysis for Gas-Insulated Switchgear Mechanical Fault Detection under Varying Current
نویسندگان
چکیده
منابع مشابه
New 550-kV Gas-insulated Switchgear
OVERVIEW: Hitachi has developed smaller and more reliable gas-insulated switchgear (GIS) in response to demands for lower costs and stable power supplies. Reliability of this GIS was improved and the enclosure diameter was reduced in order to minimize the installation space by using new analysis techniques and rationalization in insulation design and in temperature rise criteria. Furthermore, t...
متن کاملNonlinear and Non-stationary Vibration Analysis for Mechanical Fault Detection by Using EMD-FFT Method
The Hilbert-Huang transform (HHT) is a powerful method for nonlinear and non-stationary vibrations analysis. This approach consists of two basic parts of empirical mode decomposition (EMD) and Hilbert spectral analysis (HSA). To achieve the reliable results, Bedrosian and Nuttall theorems should be satisfied. Otherwise, the phase and amplitude functions are mixed together and consequently, the ...
متن کاملPredict Of Temperature - Risein the Gas Insulated Switchgear Bus Bar Using Magnetic - Thermal Multi - Physics Analysis
In this paper, Gas insulated Switchgear bus bar has been investigated using 3D coupled multiphysics finite element analysis. The coupled field analysis involved consecutive multi-physics interactions. The interaction is characterized as a two-way sequential electromagnetic-thermal field coupling. The temperature rise in the GIS bus bar is due to the Joule’s losses in the conductor and induced e...
متن کاملFeature Selection for Partial Discharge Severity Assessment in Gas-Insulated Switchgear Based on Minimum Redundancy and Maximum Relevance
Scientific evaluation of partial discharge (PD) severity in gas-insulation switchgear (GIS) can assist in mastering the insulation condition of in-service GIS. Limited theoretical research on the laws of PD deterioration leads to a finite number of evaluation features extracted and subjective features selected for PD severity assessment. Therefore, this study proposes a minimum-redundancy maxim...
متن کاملStatus Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance
Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment. It uses sulphur hexafluoride gas as its insulant and coolant because of its high dielectric strength and excellent arc quenching ability. Gas insulated switchgear i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Sciences
سال: 2020
ISSN: 2076-3417
DOI: 10.3390/app10030944