Vibration analysis of elevator rope with vibration suppressors (Identification of flexural rigidity, viscous damping and structural damping)
نویسندگان
چکیده
منابع مشابه
Viscous damping identification in linear vibration
Parametric identification of viscous damping models in the context of linear vibration theory is studied. Frequency domain identification methods based on measured frequency response functions (FRFs) are considered. Existing methods are classified into two main groups: matrix methods which use directly the measured FRF matrix, and modal methods which use modal parameters deduced from the FRFs. ...
متن کاملDamping Models for Structural Vibration
This dissertation reports a systematic study on analysis and identification of multiple parameter damped mechanical systems. The attention is focused on viscously and non-viscously damped multiple degree-offreedom linear vibrating systems. The non-viscous damping model is such that the damping forces depend on the past history of motion via convolution integrals over some kernel functions. The ...
متن کاملA broadband controller for shunt piezoelectric damping of structural vibration
Abstract In this paper a broadband active shunt technique for controlling vibration in piezoelectric laminated structures is proposed. The effect of the negative capacitance controller is studied theoretically and then validated experimentally on a piezoelectric laminated simply supported plate. The ‘negative capacitance controller’ is similar in nature to passive shunt damping techniques, as a...
متن کاملViscous vs. Structural Damping in Modal Analysis
It is shown that among the various damping mechanisms that are generally encountered in a mechanical structure, only the “viscous component” actually accounts for energy loss. The remaining portion of the damping force is due to non-linearities, which do not dissipate energy. Consequently, a linear model of a vibratory mechanical system involves only viscous damping, although the damping factor...
متن کاملVibration Damping of High-Chromium Ferromagnetic Steel
The aim of the present work is to study the effect of annealing on the vibration damping capacity of high-chromium (16%) ferromagnetic steel. The alloys were prepared from raw materials of 99.9% purity melted in a high frequency induction furnace under high vacuum. The samples were heat-treated in vacuum at various temperatures (800 to 1200oC) for 1 hour followed by slow cooling (120oC/h). The ...