VH5. Transcarotid Stenting with Dynamic Flow Reversal
نویسندگان
چکیده
منابع مشابه
A prospective evaluation of cerebral infarction following transcervical carotid stenting with carotid flow reversal.
OBJECTIVE Cerebral embolisation constitutes the main source of complications during transfemoral carotid artery stenting (CAS) and is associated with a high incidence of silent brain infarction. The goal of this study is to evaluate the incidence of new ischaemic cerebral lesions following transcervical CAS with carotid flow reversal for neuroprotection. MATERIALS AND METHODS Thirty-one conse...
متن کاملTranscranial Doppler monitoring of transcervical carotid stenting with flow reversal protection: a novel carotid revascularization technique.
BACKGROUND AND PURPOSE Transfemoral carotid stenting, despite becoming very frequent, has some limitations such as difficult groin access in few patients, lack of distal protection during filter placement, or embolization despite protection. Transcervical stenting (TCS) is a novel technique during which a common carotid to jugular vein shunt is placed creating a protective reversal flow in the ...
متن کاملPulsatile tinnitus from reversal of flow in an aberrant occipital artery: resolved after carotid artery stenting.
Carotid artery stent placement, performed for correction of an asymptomatic severe stenosis, leads to the resolution of persistent and troublesome pulsatile tinnitus. Tinnitus has been reported as a consequence of severe carotid stenoses on previous occasions. This case highlights how an aberrant occipital artery originating above a carotid artery stenosis can result in flow reversal and be a m...
متن کاملFlow reversal versus filter protection: a pilot carotid artery stenting randomized trial.
BACKGROUND Carotid artery stenting (CAS) has become an alternative treatment for patients presenting symptomatic carotid artery stenosis. The improvement in clinical outcomes with CAS has been associated with the development of embolic protection devices. The trial aim is to compare flow reversal versus filter protection during CAS through femoral access. METHODS AND RESULTS Patients were ran...
متن کاملFlow Reversal of Negative Ions
Scientists at the U.S. Department of Energy's (DOE) Princeton Plasma Physics Laboratory (PPPL) and Princeton University have proposed a groundbreaking solution to a mystery that has puzzled physicists for decades. At issue is how magnetic reconnection, a universal process that sets off solar flares, northern lights and cosmic gamma-ray bursts, occurs so much faster than theory says should be po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Vascular Surgery
سال: 2015
ISSN: 0741-5214
DOI: 10.1016/j.jvs.2015.04.349