Vessel architecture imaging using multiband gradient-echo/spin-echo EPI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction for EPI distortions using multi-echo gradient-echo imaging.

A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...

متن کامل

Whole brain, high resolution multiband spin-echo EPI fMRI at 7 T: A comparison with gradient-echo EPI using a color-word Stroop task

A whole brain, multiband spin-echo (SE) echo planar imaging (EPI) sequence employing a high spatial (1.5 mm isotropic) and temporal (TR of 2 s) resolution was implemented at 7 T. Its overall performance (tSNR, sensitivity and CNR) was assessed and compared to a geometrically matched gradient-echo (GE) EPI multiband sequence (TR of 1.4 s) using a color-word Stroop task. PINS RF pulses were used ...

متن کامل

Compressed sensing fMRI using gradient-recalled echo and EPI sequences

Compressed sensing (CS) may be useful for accelerating data acquisitions in high-resolution fMRI. However, due to the inherent slow temporal dynamics of the hemodynamic signals and concerns of potential statistical power loss, the CS approach for fMRI (CS-fMRI) has not been extensively investigated. To evaluate the utility of CS in fMRI application, we systematically investigated the properties...

متن کامل

Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI).

Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination...

متن کامل

Gradient echo imaging.

Magnetic resonance imaging (MRI) based on gradient echoes is used in a wide variety of imaging techniques and clinical applications. Gradient echo sequences form the basis for an essential group of imaging methods that find widespread use in clinical practice, particularly when fast imaging is important, as for example in cardiac MRI or contrast-enhanced MR angiography. However, the term "gradi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLOS ONE

سال: 2019

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0220939