Very low pacemaker rate following ACURATE neo transcatheter heart valve implantation
نویسندگان
چکیده
منابع مشابه
Successful percutaneous implantation of Symetis ACURATE neo transcatheter aortic bioprosthesis in a patient with existing mechanical mitral valve
A 73-year old woman who had previous mechanical mitral valve replacement (MVR) presented with worsening symptoms of dyspnea. Echocardiographic evaluation revealed severe aortic stenosis with calcified trileaflet aortic valve (aortic valve area was 0.9 cm2, mean gradient was 42 mm Hg with 45% ejection fraction). Society of Thoracic Surgeons score of the patient was 8.9%, mean logistic European s...
متن کاملLow permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.
BACKGROUND Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pace...
متن کاملAtrial Fibrillation Following Transcatheter Aortic Valve Implantation
The issue of atrial fibrillation (AF) following TAVI may seem of limited interest at first sight, and this is probably the reason why this issue has not been addressed in depth so far. First, AF is usually a more important concern in mitral than in aortic valve diseases. Second, the occurrence of AF following surgery under cardiopulmonary bypass is generally interpreted as a consequence of peri...
متن کاملCoronary Obstruction Following Transcatheter Aortic Valve Implantation
BACKGROUND Transcatheter aortic valve implantation (TAVI) was established as an important alternative for high-risk patients with severe aortic stenosis. However, there are few data in the literature regarding coronary obstruction, that although rare, is a potentially fatal complication. OBJECTIVE Evaluate this complication in Brazil. METHODS We evaluated all patients presenting coronary ob...
متن کاملPredictive factors for pacemaker requirement after transcatheter aortic valve implantation
BACKGROUND Transcatheter aortic valve implantation (TAVI) has been established as a treatment option for inoperable patients with symptomatic aortic valve stenosis. However, patients suffer frequently from conduction disturbances after TAVI. METHODS Baseline, procedural as well as surface and intracardiac ECG parameters were evaluated for patients treated with TAVI and a comparison between pa...