Very high quality factor measured in annealed fused silica
نویسندگان
چکیده
منابع مشابه
High quality factor measured in fused silica
We have measured the mechanical dissipation in a sample of fused silica drawn into a rod. The sample was hung from a multiple-bob suspension, which isolated it from rubbing against its support, from recoil in the support structure, and from seismic noise. The quality factor, Q, was measured for several modes with a high value of 57 million found for mode number 2 at 726 Hz. This result is about...
متن کاملHigh quality factor silica microspheres functionalized with self-assembled nanomaterials.
With extremely low material absorption and exceptional surface smoothness, silica-based optical resonators can achieve extremely high cavity quality (Q) factors. However, the intrinsic material limitations of silica (e.g., lack of second order nonlinearity) may limit the potential applications of silica-based high Q resonators. Here we report some results in utilizing layer-by-layer self-assemb...
متن کاملFabrication of silica ultra high quality factor microresonators.
Whispering gallery resonant cavities confine light in circular orbits at their periphery. The photon storage lifetime in the cavity, quantified by the quality factor (Q) of the cavity, can be in excess of 500ns for cavities with Q factors above 100 million. As a result of their low material losses, silica microcavities have demonstrated some of the longest photon lifetimes to date. Since a port...
متن کاملMonolithic Cylindrical Fused Silica Resonators with High Q Factors
The cylindrical resonator gyroscope (CRG) is a typical Coriolis vibratory gyroscope whose performance is determined by the Q factor and frequency mismatch of the cylindrical resonator. Enhancing the Q factor is crucial for improving the rate sensitivity and noise performance of the CRG. In this paper, for the first time, a monolithic cylindrical fused silica resonator with a Q factor approachin...
متن کاملLow scatter and ultra-low reflectivity measured in a fused silica window.
We investigate the reflectivity and optical scattering characteristics at 1064 nm of an antireflection coated fused silica window of the type being used in the Advanced LIGO gravitational-wave detectors. Reflectivity is measured in the ultra-low range of 5-10 ppm (by vendor) and 14-30 ppm (by us). Using an angle-resolved scatterometer we measure the sample's bidirectional scattering distributio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Classical and Quantum Gravity
سال: 2004
ISSN: 0264-9381,1361-6382
DOI: 10.1088/0264-9381/21/16/004