VERTICAL DISTRIBUTION OF SEISMIC DESIGN LOAD FOR SEISMICALLY ISOLATED BUILDINGS CORRESPONDING TO DIVERSITY OF SEISMIC ISOLATION DEVICES
نویسندگان
چکیده
منابع مشابه
New Lateral Force Distribution for Seismic Design of Structures Based on Seismic Demand Ratio
The design of earthquake-resistant buildings starts with defining the maximum lateral earthquake forces or their resultant. The amount of these forces depends on various factors, including coefficient of system behavior which depends on overstrength and its ductility. In this study, a method is presented for designing an earthquake-resistant system in which the distribution of lateral forces is...
متن کاملEvaluation of Seismic Performance of Combined Horizontal and Vertical Hexagrid Structural System for High-rise Buildings
Summary In this study, the seismic performance of hexagrid structures which are composed of horizontal and vertical hexagrid by using a transitional story, has been investigated. To this end, 10 models of 50-story hexagrid structures were designed. 9 models with horizontal hexagrid cells which transited to vertical cells using a transitional story, and a model of completely horizontal hexagrid ...
متن کاملDesign Principles of Seismic Isolation
In earthquake resistance design of structures, two general concepts have been used. The first is to increase the capacity of the structures to resist the earthquake load effects (mostly horizontal forces) or to increase the dynamic stiffness such as the seismic energy dissipation ability by adding damping systems (both devices and/or structural fuses). The second concept includes seismic isolat...
متن کاملSeismic fragility assessment of RC moment resisting frame buildings designed for different editions of Iranian seismic design code
Background and objective: Developing fragility and vulnerability functions are important tools in seismic reliability assessment of buildings and are widely used in regional seismic risk studies. To date sufficient studies for developing analytical fragility functions for Iranian code-conforming buildings have not been carried out. Performing such studies are necessary to assess the adequacy of...
متن کاملMulti-axial Active Isolation for Seismic Protection of Buildings
Structural control technology has been widely accepted as an effective means for the protection of structures against seismic hazards. Passive base isolation is one of the common structural control techniques used to enhance the performance of structures subjected to severe earthquake excitations. Isolation bearings employed at the base of a structure naturally increase its flexibility, but con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2012
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.77.859