Vertebral body stenting / stentoplasty

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of Osteoporotic Vertebral Compression Fractures with Stentoplasty

Study Design: A prospective study of clinical and radiographic results after vertebral body stenting (VBS) for treatment of osteoporotic vertebral compression fractures (VCFs). Objectives: To evaluate the effectiveness of stentoplasty as a new technique to treat symptomatic VCFs. Background Data: Conventional balloon kyphoplasty is a procedure meant to treat osteoporotic and/or cancer related V...

متن کامل

Stenting for symptomatic vertebral artery stenosis

OBJECTIVE To compare in the Vertebral Artery Ischaemia Stenting Trial (VIST) the risks and benefits of vertebral angioplasty and stenting with best medical treatment (BMT) alone for symptomatic vertebral artery stenosis. METHODS VIST was a prospective, randomized, open-blinded endpoint clinical trial performed in 14 hospitals in the United Kingdom. Participants with symptomatic vertebral sten...

متن کامل

Transradial approach for vertebral artery stenting

INTRODUCTUION Symptomatic severe vertebral artery (VA) stenosis may be treated safely with stent supported angioplasty via femoral access. There is limited clinical data on transradial approach for VA angioplasty in case of peripheral artery disease. AIM To evaluate the safety and efficacy of transradial angioplasty of symptomatic VA stenosis. MATERIAL AND METHODS Fifteen patients (age 66 ±...

متن کامل

Simultaneous vertebral and subclavian artery stenting

INTRODUCTION Vertebrobasilar territory ischemia leads to disabling neurological symptoms and may be caused both by vertebral artery (VA) and subclavian artery (SA) stenosis. The coexisting symptomatic ipsilateral VA and proximal SA stenosis should be considered as a true bifurcation lesion for percutaneous treatment. AIM To evaluate the safety and efficacy of simultaneous angioplasty of verte...

متن کامل

Radiographic and safety details of vertebral body stenting: results from a multicenter chart review

BACKGROUND Up to one third of BKP treated cases shows no appreciable height restoration due to loss of both restored height and kyphotic realignment after balloon deflation. This shortcoming has called for an improved method that maintains the height and realignment reached by the fully inflated balloon until stabilization of the vertebral body by PMMA-based cementation. Restoration of the phys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Swiss Medical Weekly

سال: 2012

ISSN: 1424-7860,1424-3997

DOI: 10.4414/smw.2012.13658